PROGRAMMING AND STARTUP
4
TOTAL OPEN/CLOSE PROGRAMMING
The programming of the gate open/close is done
using the transmitter, the ST1 mini-pushbutton or
the total key command (A.T.).
Start programming mode
Programme the slowdown start points
Finish the programming mode
The total opening and closing of the gate will be
memorised.
The positions in which the gate begins to slow
down, both on opening and in closing, will also
be memorised.
56
Installation Manual
All manuals and user guides at all-guides.com
1 Ensure that DIP9 is configured correctly (see "Limit
2 Close the gate by pressing PUL1.
3 Place DIP7 in "ON" to enable the encoder.
4 Place DIP8 in "ON" (slowdown).
5 Place DIP1 and DIP2 in "ON"; DIP3, DIP4, DIP5 and
1 Start to open the gate: press ST1; the gate begins
2 Start slowdown in opening: press ST1 (or A.T. or
3 Wait for the gate to come to a halt due to the
4 Start closing the gate: press ST1; the gate begins
5 Start slowdown in closing: press ST1 (or A.T. or
6 Wait for the gate to come to a halt due to the
1 Place DIP1 and DIP2 in "OFF".
Before making the programming, ensure there
is no person, animal or object in the radius of
action of the gate and the mechanism.
switches configuration (DIP9)" on page 53).
If the encoder is not enabled (DIP7=OFF),
operation times will be memorised.
DIP6 in "OFF".
DL3
lights
up,
indicating
programming mode.
to open.
the transmitter) when the opening limit switch
magnet is approximately 50 cm from the end of the
run, in order to start slowdown (DA1).
action of the opening limit switch.
to close.
the transmitter) when the closing limit switch
magnet is approximately 50 cm from the end of the
run, in order to start slowdown (DC1).
action of the closing limit switch.
DL3 will remain off.
that
it
is
in