WARNING!
Remember that failure to perform the intended inspections at an Authorised Campagnola Assistance Centre ter-
minates the warranty (See par. 1.5).
5.2
Stopping the shear
The shear must always be put back into the specific holster (5) with the blades (19) closed. Therefore, keep the trigger
(15) pressed for 5 sec to activate the STOP function, and then switch off the battery (1) using the ON/OFF button (11).
5.3
Charging the battery and operation of the battery charger
Charge the battery pack every day during normal use.
The charge cycle is complete when the display (9) of the battery (1) is off and the LED on the battery charger (34) is
green. A complete recharge requires 2-3 hours.
WARNING!
After having inserted the male connector of the battery charger (34) in the female connector of the battery (8),
position the front part of the battery (1) on a stable surface.
WARNING!
Use the battery charger in a closed and dry environment.
WARNING!
Unplug the battery charger when the battery pack has been recharged.
Do not leave the battery charger plugged in when the recharge is finished.
5.4
Troubleshooting
WARNING!
All the following maintenance operations shall be carried out by a mechanical maintenance technician.
FAULT
The shear does not work
The shear does not have ade-
quate force
Excessive battery consumption
The shear blocks and the dis-
play read A2
The shear does not close and
the display reads A1
The shear is in SAFE mode
The shear is in STOP mode
The battery pack is off
The battery display is flashing
NOTE: If the above-mentioned remedies do not solve the problem, contact an Authorised Service Point.
5.5
Improper uses
•
Never use the tool when your balance is unstable.
•
Never cut materials being other than wood.
•
Never use the tool as a lever or for lifting, moving or breaking any objects.
•
Never use the tool if the atmosphere is explosive or inflammable.
•
Do not use the tool in the rain or fog.
Use and Maintenance Manual – Original
Instructions Rev.: 00, Date 10/10/2018
CAUSE
Battery pack (1) discharged
Battery pack (1) not on
Shear not powered
Battery pack (1) discharged
Cutting blade (17) worn.
Blade pin (25) too tight.
Cutting blade (17) worn
Overheating of motor due to
cutting large branches
Block due to high internal
temperature
Shear idle for over 5 min.
Trigger kept pressed for over
5 seconds
Shear
idle
for
over
minutes.
Excessively
high
battery
temperature reached.
REMEDY
Recharge the battery.
Switch on the battery pack by means of the ON/OFF button (11).
Check the connection between the electronic control unit (21)
and the shear.
Recharge the battery (1).
Sharpen the moving blade (17) or replace it if excessively worn.
Execute the CLAMPING function (see par. 5.1).
Sharpen the moving blade (17) or replace it if excessively worn.
Wait for the temperature to drop about 5°C to resume work.
Wait a few seconds and continue work while privileging small
branches for awhile, in order to move away from the protective
threshold.
Press the trigger (15) at least 3 times to reactivate the shear.
Press the trigger (15) at least 3 times to reactivate the shear.
20
Turn on the battery (1) by means of the ON/OFF switch (11).
Wait from 5 to 30 minutes for the battery to restart automatically.
Pag. 33