HOUSING FAN
The three IP67-rated housing fans and heat sink are located on the rear of the LED unit. To ensure
air circulation,
do not cover the device and clean it regularly.

SIGNAL AND POWER CABLE

There are no plugs or sockets at the cable ends of the DMX signal cable and the cable for
the spotlight's power supply. Therefore, the spotlight may only be wired by trained
specialist personnel. Extensive knowledge of handling data and power cables, as well
as the creation of waterproof connections and junctions according to protection class
IP67, is required.
If you do not have these qualifications, do not attempt to install cables yourself. Refer
instead to a qualified professional. Liability is excluded for damage resulting from
improper handling in all work steps necessary for safe operation. Ensure that no mains
voltage is present in cables and spotlights during all work steps that are necessary for
cabling.
DMX SIGNAL CABLE
DMX input and output
white
red
shield
red
white
DMX IN
minus (-)
DMX IN
plus (+)
DMX IN/OUT
DMX OUT
plus (+)
DMX OUT
minus (-)
-
white
DMX IN
+
red
shield
DMX IN/OUT
+
red
DMX OUT
-
white