USING THE BATTERY VOLTAGE TESTER
1. With the charger unplugged from the
AC outlet, connect the charger to the
battery, following the instructions given in
previous sections.
2. Plug the charger AC power cord into the
AC outlet.
3. If necessary, press the BATTERY TYPE
button until the correct type is indicated.
4. Read the voltage on the digital display.
Keep in mind that this reading is only a
battery voltage reading; a false surface
charge may mislead you. Compare the
reading to the following chart.
6V Battery
12V Battery
Voltage
Voltage
Reading
Reading
6.4 or More
12.8 or More
6.1 to 6.3
12.2 to 12.7
Less than
Less than 6.1
12.2
TESTER AND CHARGER
When first turned on, the unit operates only
as a tester, not as a charger. Selecting a
charge rate activates the battery charger
and deactivates the tester. Pressing the
RATE SELECTION button when the
ENGINE START LED is lit (except during
the 180 second cool down) will shut off the
charger and activate the tester.
A minimal amount of care can keep your
battery charger working properly for years.
• Clean the clamps each time you are
finished charging. Wipe off any battery fluid
that may have come in contact with the
clamps to prevent corrosion.
• Occasionally cleaning the case of the
charger with a soft cloth will keep the finish
shiny and help prevent corrosion.
All manuals and user guides at all-guides.com
Battery
Condition
Charged
Needs
Charging
Discharged

MAINTENANCE AND CARE

• Coil the input and output cords neatly when
• Store the charger unplugged from the AC
• Store inside, in a cool, dry place. Do not
• 8 •
POWER-UP IDLE TIME LIMIT
If no button is pressed within 10 minutes after
the battery charger is first powered up, the
charger will automatically switch from tester to
charger if a battery is connected. In that case,
the charger will be set to the Charging/
Maintaining rate and gel cell battery type.
TESTING AFTER CHARGING
After the unit has been changed from tester to
charger (by selecting a charge rate), it remains
a charger. To change the battery charger back
to a tester, press the RATE SELECTION
button until all charge rate LEDs are off.
NOTE: The battery tester is only designed
to test batteries. Testing a device with a
rapidly changing voltage could yield
unexpected or inaccurate results.
USING THE ALTERNATOR
PERFORMANCE TESTER
1. With the charger unplugged from the
AC outlet, connect the charger to the
battery, following the instructions given in
previous sections.
2. Plug the charger AC power cord into the
AC outlet.
3. Start the vehicle and turn on the vehicle's
headlights. Read the voltage on the digital
display. If you get a reading between
13.2 volts and 14.6 volts, the alternator
is working properly. If the reading is less
than 13.2 volts or more than 14.6 volts,
have the charging system checked by a
qualified technician.
storing the charger. This will help prevent
accidental damage to the cords and charger.
power outlet in an upright position.
store the clamps clipped together, on or
around metal, or clipped to the cables.