Output Bin Present Diagnostic Test (5300N only)
This tests the output bin door sensor.
1.
Open the output bin. The sensor beeps and operator panel displays [0] to
show the change in status.
2.
Close the output bin. The sensor beeps and operator panel displays [1] to
show the change in status.
3.
Press and hold the operator button to exit the test.
Exit Diagnostic Test Mode
1.
If a diagnostic test is currently running, press the operator button once to
stop the test.
2.
When the diagnostic test is stopped, press the operator button seven times
and hold it on the seventh press. The operator panel displays [RELEASE
BUTTON]. The autoloader exits diagnostic test mode and the autoloader
resets.