3.
If necessary, perform a front to back alignment.
Turn the front to back alignment
screw until there is a 1/16" (1.5
mm) gap between the front edge
of the disc and the raised edge
of the disc retainer.
Tip: You can use the Torx
T25 driver or 5/32" Allen
wrench to turn the front to
back alignment screw.
4
Repeat steps 1 - 3 until the printer
is aligned.
5.
When the printer is aligned, press
the operator button to raise the lift arm up about 1.0" (2.5 cm).
6.
Exit diagnostic mode. Refer to
instructions.