Stanley SPL3 Manual Del Usuario página 12

Ocultar thumbs Ver también para SPL3:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Level Beam Accuracy
(Single Beam) - (See figure
Place laser tool as shown with laser ON. Mark point P
N
1
on the first wall.
Rotate laser tool 180° and mark point P
N
2
wall.
Move laser tool close to second wall and adjust the
N
3
height of the unit until point P
Rotate laser tool 180° and mark point P
N
4
wall.
Measure the vertical distance between P
N
5
get D
.
1
• If the measurement is greater than the maximum
offset distance the tool must be returned to your
Stanley Distributor for calibration.
Maximum Offset Distance:
= 0,2 mm m x (D
Maximum
= 0,0024 in ft x (D
Compare : (See figure
D
- D
≤ ± Maximum
3
4
Example:
• D
= 10 m, D
= 0,5 m
1
2
• D
= 0,4 mm
3
• D
= - 0,6 mm
4
• 0,2 mm m x (10 m - (2 x 0,5 m) = 1,8 mm (maximum
offset distance)
• (0,4 mm) - (- 0,6 mm) = 1,0 mm
• 1,0 mm ≤ 1,8 mm (TRUE, tool is within calibration)
12
)
N
on the second
2
is aligned with P
.
3
2
.on the first
4
and P
to
1
4
m - (2 x D
m))
1
2
ft - (2 x D
ft))
1
2
)
N
5
1
STHT77342

Publicidad

Tabla de contenido
loading

Tabla de contenido