2. SERVICE CALL
[1] Error Code Indication
If the error code "E" is indicated on the display, before
calling for service, check the following.
Code
Remedy
E0
Possibility of water leaks. Turn OFF Operation Switch,
and turn it ON again. If error code appears again, call for
service.
E1
Low ice production. Turn OFF Operation Switch, and
turn it ON again. If error code appears again, call for
service.
E2
Turn OFF Operation Switch, and turn it ON again. If error
code appears again, call for service.
E3
Gear Motor could be overloaded or overheated. Turn
OFF Operation Switch, and turn it ON again after 10
minutes. If error code appears again, call for service.
E5
Controller Board may have a fault. Turn OFF Operation
Switch, and turn it ON again. If error code appears again,
call for service.
E6
Miswiring. Call for service.
EA
Supply voltage is too low. Check that voltage is in required
range and icemaker is not sharing a single receptacle
with other appliances. Turn OFF Operation Switch, and
turn it ON again.
Eb
Turn OFF Operation Switch, and turn it ON again. If error
code appears again, call for service.
EE
Gear Motor is in abnormal rotation. Turn OFF Operation
Switch, and turn it ON again. If error code appears again,
call for service.
EF
Supply voltage is too low. Check that voltage is in required
range and icemaker is not sharing a single receptacle
with other appliances. Turn OFF Operation Switch, and
turn it ON again.
EJ
Could lead to failure of icemaking mechanism. Ice
production continues, but call for service immediately.
EL
Bin Control Switch has failed. Call for service.
En
Turn OFF Operation Switch, and turn it ON again. If error
code appears again, call for service.
EP
Call for service.
EU
Turn OFF Operation Switch, and turn it ON again. If error
code appears again, call for service.
[2] No Error Code Indication
If the icemaker does not work properly or does not
work at all and no error code is indicated on the display,
before calling for service, check that:
* The power is supplied to the unit.
* The water is turned on.
* The Ball Valve is opened.
For further assistance or advice, contact your local
Hoshizaki service agent.
All manuals and user guides at all-guides.com
3. WARRANTY
Hoshizaki warrants to the original owner/user that all
Hoshizaki branded products shall be free of defects in
material and/or workmanship for the duration of the
"warranty period". The warranty shall be effective for
two years from the date of installation in EU countries,
but only one year in other countries.
Hoshizaki's liability under the terms of the warranty
are limited and shall exclude routine servicing, cleaning,
essential maintenance and/or repairs occasioned by
misuse and installations not in accordance with
Hoshizaki guidelines.
Warranty repairs should be completed by an approved
Hoshizaki dealer or service agency using genuine
Hoshizaki components.
To obtain full details of your warranty and approved
service agency, please contact your dealer/supplier,
or the nearest Hoshizaki office. Alternatively, contact
Customer Care in the U.K.
TEL: +44 (0) 1707322493
FAX: +44 (0) 1707322315
Hoshizaki Care Branch Offices:
Benelux
TEL: +31 (0) 206918499
FAX: +31 (0) 206918768
Germany
TEL: +49 (0) 215492810
FAX: +49 (0) 2154928128
France
TEL: +33 (0) 148137130
FAX: +33 (0) 148130992
4
91U2CM21B0303

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fm-2000alf-n

Tabla de contenido