14. TROUBLESHOOTING

PROBLEM
Battery ring
terminals do not
spark when touched
together.
Both LEDs come on
for 2 seconds, then
turn off.
The charger will
not turn on when
properly connected.
I cannot select a 6V
or 12V setting.

15. BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem, or for more information
about troubleshooting, contact customer service for assistance:
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT
SHIP UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA)
number from Customer Service at Schumacher Electric Corporation.
POSSIBLE CAUSE
The charger is equipped with
an auto-start feature. It will not
supply current to the battery
ring terminals until a battery
is properly connected. The
ring terminals will not spark if
touched together.
The charger is plugged into an
AC outlet.
AC outlet is dead.
Poor electrical connection.
Bad battery.
The charger is equipped with
Auto Voltage Detection, which
automatically detects the voltage
and charges the battery.
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
• 13 •
SOLUTION
No problem; this is a normal
condition.
No problem; this is normal.
Check for open fuse or
circuit breaker supplying
AC outlet.
Check power cord and
extension cord for loose
fitting plug.
Have battery checked.
No problem; this is normal.