G-U BKS B-2193 Serie Manual De Instalación página 50

Cerradura con pestillo motorizada para puertas de madera y acero
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation instructions
B-2193x | B-2393x
Motor-driven shoot-bolt lock for timber and steel doors
ISR 15
50
y
y
If no errors occur during the test run, the red LED at the controller changes to "o" and the signal
contact 1 "Locked by motor" closes.
Fig.7: Test run successful
If an error occurs, the controller outputs a corresponding signal (see point 5.1).
Eliminate the error displayed and repeat the test run (see point 6.5).
Once the test run has been completed successfully, confirm this with a control signal at input I2.
The controller emits a short signal tone ( ~ ¼ s ) and the display changes to "L".
y
y
Now remove the copper-coloured transport securing devices from the latch and
deadbolt triggers.
y
y
Then remove the service plug.
Keep the service plug and do not throw it away! The service plug is required to activate later the
programming mode (see point 6).
Fig.8: Removing the service plug
y
y
The motor-driven shoot-bolt lock can now be used.
EN
06.2019 | 22288S | Designed in Germany