Technical data
Power supply directly from the line
Operating current:
Max:
Stand by:
OFF (night):
Permanent memory for programming data
Directory capacity:
LCD Display:
LED's:
Alphanumerical keypad:
Service buttons:
Maximum load contacts relay: 12Vac/12÷24Vdc - 1A
Operating temperature:
Maximum admissible humidity:
Note. All devices connected in a system where
there is a switchboard must be labelled PDX1 or
higher.
SAFETY NOTICES
Read the instructions contained in this manual carefully
because they provide important information about safe
installation, use and maintenance. Keep this manual ap-
propriately for future reference.
Install your switchboard in a dry place away from heat
sources or devices t hat produce heat and magnetic fi elds.
Do not clean the switchboard with water or chemical
solvents, use a dry cloth for cleaning.
This device must be exclusively operated for its intended
use. The manufacturer cannot be held responsible for
possible damage caused by improper, erroneous and
unreasonable use.
Keep packing parts away from children (i.e. plastic bags,
expanded polystyrene, etc.).
Do not open the device when it is ON.
The installation must be made by specialized personnel
in compliance with the regulations in force.
Always refer to specialized personnel in case of break-
down, irregular operation or change in the installation.
The device complies with the rules for CE marking.
INDEX
0.5A
0.05A
0.02A
500 names
matrix 64x128 points
8
15 buttons
7
1
0° ÷ +50°C
90%RH
Dimensions.
To get pictures from the door stations it is possible to install
16
the monitor art. ST7100CW, the wall bracket art. WB7262
17
and the table adaptor art. TA7100W. No additional program-
ming is required when installing the ST7100CW monitor.
20
20
21
Connection of a CCTV monitor
It is also possible to place a CCTV monitor with analogue
input near by PDX2000.
Attention! Please use a monitor with no earth connection
(Class II) or use a ground loop separator. CCTV monitor can
work either in continuous or timed mode. In the case of
continuous mode (direct powering from the mains) moni-
tor is always powered-ON even when the door station is
not in operation (no image).
In timed mode monitor is powered-ON only when the door
station is in connection (with image). To operate in this
way it is necessary to connect the CCTV monitor as shown
in the following diagram and program the internal relay of
switchboard as reported in the chapter "Operating mode
of internal relay".
V
M
C
max.12Vdc
NC
NO
PDX2000
Monitor power supply
78,82
80,03
34,09
110÷230Vac
CCTV MONITOR
Mi 2453/2
- 15 -