Troubleshooting - Dometic MSI924M Instrucciones De Montaje Y De Uso

Convertidor de ondas seno
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60

Troubleshooting

12
Troubleshooting
!
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
I
NOTE
If you have detailed questions on the specifications of the inverter
please contact the manufacturer (addresses on the back of the
instruction manual).
The "Load Status" LED (fig. 5 3, page 4) lights up red to indicate the fault:
LED display
Quick flash
Slow flash
Occasional flash
Constantly lit
20
Cause
Input voltage is too high
Input voltage too low
Overheating
Short circuit or reversed
polarity
Excessive load
Remedy
Check the input voltage and reduce
it.
The battery needs recharging.
Check the cables and connections.
Switch off the inverter and the con-
sumer.
Wait 5 to 10 minutes and switch the
inverter on again without any elec-
tric consumers.
Reduce the load and make sure the
inverter has better ventilation. Then
switch the consumer back on.
Switch off the inverter and remove
the consumer.
Then switch the inverter back on
without the consumer. If no exces-
sive load is now shown, then there
is a short circuit in the consumer or
the total load was higher than the
power specified on the data sheet.
Check the cables and connections.
MSI924M
EN

Publicidad

Tabla de contenido

Solución de problemas

loading