Troubleshooting - Dometic SINEPOWER MSI 2312T Instrucciones De Montaje Y De Uso

Convertidor de ondas seno
Ocultar thumbs Ver también para SINEPOWER MSI 2312T:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
SinePower
12

Troubleshooting

!
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
I
NOTE
If you have detailed questions on the specifications of the inverter
please contact the manufacturer (addresses on the back of the instruc-
tion manual).
The LED (fig. 5 2, page 4) lights up red to indicate the fault:
LED display
Cause
Quick flash
Input voltage is too high Check the input voltage and reduce it.
Slow flash
Input voltage too low
Occasional flash Overheating
Constantly lit
Short circuit or reversed
polarity
Excessive load
EN
Remedy
The battery needs recharging.
Check the cables and connections.
Switch off the inverter and the consumer.
Wait 5 to 10 minutes and switch the inverter
on again without any electric consumers.
Reduce the load and make sure the inverter
has better ventilation. Then switch the con-
sumer back on.
Switch off the inverter and remove the
consumer.
Then switch the inverter back on without the
consumer. If no excessive load is now shown,
then there is a short circuit in the consumer or
the total load was higher than the power
specified on the data sheet. The fuse in the
device must be pressed in again by hand after
it has been triggered by excess current.
Check the cables and connections.