Troubleshooting Guide - Smith XP100P Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
For assistance with your product, visit our website at
PROBLEM
Sprayer will not turn on
when Power Button is
pressed (no audible hum
of the pump.)
Sprayer turns on (audible
hum of pump heard) but
will not spray.
Sprayer turns on but only
sprays at low pressure.
Hose Leaks at Tank
connection.
Hose Leaks at Shut-off.
Nozzle drips when Shut-
off Lever is released.
Nozzle Tip leaks.
Poor Spray Pattern
10

TROUBLESHOOTING GUIDE

BE SURE TO FOLLOW SAFETY RULES AND INSTRUCTIONS
POSSIBLE CAUSE
Battery not charged. Light does not
turn ON.
Pump is damaged, over heated, or
non-functional. Visually inspect the
Pump for damage. Use the Charger
to diagnose any Battery problem.
See Charging the Pump Internal
Battery.
Tank is already pressurized so the
Pump has turned off auto-matically.
Pump is connected to Charger.
No liquid in Tank.
Shut-off clogged.
Nozzle clogged.
Pump is not tightened to Tank, leaks
at Seal.
Tank not yet pressurized.
Air leaking from Tank at Seal.
Tank Seal or Seal surfaces are
damaged.
Shut-off clogged.
Nozzle clogged.
Cracked, swollen or faulty Hose.
Damaged connection.
Cracked, swollen or faulty Hose.
Damaged connection.
Dirt or debris in Shut-off.
Damaged O-Ring or Seal in Shut-off.
Flat Seal missing.
Flat Seal damaged.
Tank is not pressurized.
Nozzle partially clogged.
Nozzle damaged.
Shut-off clogged.
www.thefountainheadgroup.com
Charge Pump if no light is ON. See
Charging the Pump Internal Battery.
Replace Pump if damaged or non-
functional. Allow Battery to cool if
overheated.
Open the Shut-off (depress Lever) to see if
the Sprayer starts spraying.
Disconnect Charger.
Add liquid to Tank. See Filling the Sprayer.
Clean Shut-off. See Shut-off Maintenance.
Clean Nozzle. See Nozzle Maintenance.
Tighten Pump to Tank.
Allow time for Pump to pressurize Tank
(at least to 20 seconds).
Tighten Pump to Tank.
Replace Tank Seal.
Clean Shut-off. See Shut-off Maintenance
Clean Nozzle. See Nozzle Maintenance..
Replace Shut-off Assembly.
Replace Shut-off Assembly.
Replace Shut-off Assembly.
Replace Shut-off Assembly.
Clean Shut-off Assembly.
Replace Shut-off Assembly.
Install Flat Seal behind Nozzle Tip. See
Assemble Wand, Shut-off and Nozzle
Replace Flat Seal.
Turn on Pump.
Clean Nozzle. See Nozzle Maintenance.
Replace Nozzle.
Clean Shut-off. See Shut-off Maintenance.
or call 1-800-311-9903.