– Press operating mode button 3 as often as required until the
requested operating mode is set.
Operating Mode
1 Horizontal laser beam,
pulsating
2 Vertical laser beam with 90° off-
set vertical laser beam,
pulsating
3 Cross-line with 90° offset verti-
cal laser beam
4 Inclined cross-line with 90° off-
set vertical laser beam (manual
operation without self-levelling)
Note: When the measuring tool is not in manual operation and not within
the self-levelling range, the laser beam flashes rapidly.
– To switch off the measuring tool, press the operating mode button
3 until the tool switches off.
Starting Operation of the Laser Receiver
(see figure B)
Protect the laser receiver against moisture.
Do not subject the laser receiver to extreme temperatures or
variations in temperature. As an example, do not leave it in vehi-
cles for longer periods. In case of large variations in temperature,
allow the laser receiver to adjust to the ambient temperature before
putting it into operation. In case of extreme temperatures or variations
in temperature, the accuracy of the laser receiver can be impaired.
Under unfavourable light conditions (bright environment, direct sunlight)
and for larger distances, use the laser detector for improved finding of
the laser beam.
Note: The laser detector can only be used when the measuring tool is
in an operating mode with pulsating laser beam.
22 | English
LED for laser beam
Horizontal 2 Vertical 4
green
green
red
2 610 A13 773 • 17.2.10
green
green
red