GB
1� About this document
Please read carefully and keep in a safe place�
– Under copyright. Reproduction either in whole or in part
only with our consent.
– Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
Reference to other information in the
...
document�
2� General safety precautions
Disconnect the power supply before
!
attempting any work on the unit�
• Installing these units involves work on the mains voltage
supply; installation must therefore be carried out profes-
sionally in accordance with the applicable national wiring
regulations and electrical operating conditions (e.g.: DE-
VDE 0100, AT-ÖVE/ÖNORM E 8001-1, CH-SEV 1000).
• The light must be positioned so that it is not expected
that anybody can stare into the light for any prolonged
period from a distance of less than 0.3 m.
• The floodlight enclosure heats up when the light is
on. Only adjust the angle of the LED panel once it has
cooled down. Do not look into the LED light at short
range or for any prolonged period (> 5 min). You could
damage your retina.
• Do not install the unit on (normally) flammable surfaces.
3� XLED home curved S
Proper use
– Sensor-switched LED floodlight for mounting on indoor
and outdoor walls
Non-intended use
– The sensor-switched LED floodlight cannot be dimmed.
Not dimmable
Operating principle
Movement activates light. With the fully swivelling panel, the
floodlight can be used at home to provide perfect illumina-
tion for lighting up property, or commercially for lighting up
business premises. In conjunction with the opal cover, this
extremely efficient technology provides wide-area lighting.
Package contents (Fig� 3�1)
– Three screws
– Three wall plugs
– Three spacers
– One sealing plug
– Adhesive shroud
Product dimensions (Fig� 3�2)
Product components (Fig� 3�3)
A LED panel
B Wall mount
C Connecting terminal
D Plug-in terminal
E Twilight setting
F Time setting
G Sensor
Detection zone (Fig� 3�4/3�5/3�6)
Luminous intensity distribution (Fig� 3�7)
4� Electrical connection
Wiring diagram (Fig� 4�1)
The mounting location should be at least 50 cm away from
other lights because heat radiated from these may activate
the system. To obtain the specified max. reach of 8 m, the
sensor should be installed at a height of approx. 2.20 m.
Install the unit on a firm surface to avoid unintentional
triggering.
The mains supply lead is a 2 to 3-core cable:
L = phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
Important:
If you are in any doubt, identify the conductors using a volt-
age tester; then disconnect from the power supply again.
Connect the phase conductor (L) and neutral conductor
(N) to the plug-in terminal. The protective earth conductor
may be sealed off with insulation tape and placed next to
the connected conductors.
Important:
Incorrectly wired connections will produce a short circuit
later on in the product or your fuse box. In this case, you
must identify the individual cables and re-connect them. A
suitable power switch for switching the light ON and OFF
can be installed in the mains supply lead.
Note:
The light source in this light cannot be replaced. If the light
source needs to be replaced (e.g. at the end of its service
life), the complete light must be replaced.
- 11 -