Connecting Charger To Power Supply; Charging The Battery - Stihl MSA 160 C Manual De Instrucciones

Ocultar thumbs Ver también para MSA 160 C:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 150
English
Connecting Charger to
Power Supply
Mains voltage and operating voltage
must be the same.
Insert the mains plug (1) in the wall
N
outlet (2).
1
A self test is performed after the charger
is connected to the power supply. During
this process the light emitting diode (1)
on the charger lights up green for about
1 second, then red and goes off again.
70
All manuals and user guides at all-guides.com

Charging the Battery

The battery is given a charge of about
30% before leaving the factory.
Recommendation: Fully charge the
battery before using your power tool for
2
the first time.
1
Connect the charger to the power
N
supply – mains voltage and
operating voltage of the charger
must be the same – see
"Connecting Charger to Power
Supply".
Operate the charger indoors only in dry
locations at an ambient temperature
between +5°C and +40°C.
Push the battery (1) into the
N
charger (2) until you feel noticeable
resistance – then push it as far as
stop.
3
The light emitting diode (3) on the
charger comes on when the battery is
inserted – see "Light Emitting Diodes
(LED) on Charger"
Charging begins as soon as the light
emitting diodes (4) on the battery light
up green – see "Light Emitting Diodes
(LED) on Battery".
The charge time is dependent on a
number of factors, including battery
condition, ambient temperature, etc.,
and may therefore vary from the charge
time in the "Specifications".
2
The battery becomes hot during
operation. If a hot battery is inserted in
the charger, it may be necessary to cool
it down before charging. The charging
process begins only after the battery has
cooled down. The time required for
cooling may prolong the charge time.
The battery and charger become warm
during the charging process.
AL 300 charger
This charger is equipped with a battery
cooling fan which is audible when it is
running.
4
MSA 160 C

Publicidad

Tabla de contenido
loading

Tabla de contenido