POWER REQUIREMENTS
DEDICATED CIRCUIT AND ELECTRICAL INFO
A "Dedicated Circuit" means that each outlet you plug into should
not have anything else running on that same circuit. The easiest
way to verify this is to locate the main circuit breaker box, and turn
off the breaker(s) one at a time. Once a breaker has been turned
off, the only thing that should not have power to it are the units in
question. No lamps, vending machines, fans, sound systems, or
any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit
must have an individual neutral/ground connection coming from
it, and terminating at an approved earth ground. You cannot
"jumper" a single neutral/ground from one circuit to the next.
ELECTRICAL REQUIREMENTS
For your safety and to ensure good treadmill performance, the ground
on this circuit must be non-looped (isolated). Please refer to NEC
article 210-21 and 210-23. Your treadmill is provided with a power cord
with a plug listed below and requires the listed outlet. Any alterations
of this power cord could void all warranties of this product.
110 V UNITS
110V treadmills require the use of a 100-125 V, 60 Hz and a minimum
15 A "Dedicated Circuit" , with a non-looped (isolated) neutral/ground
for power. This outlet should be a NEMA 5-15R and have the same
configuration as the plug. No adapter should be used with this product.
220 V UNITS
220 V treadmills require the use of a 216-250 V, 50 Hz and a 20 A
"Dedicated Circuit" , with a non-looped (isolated) neutral/ground
for power. This outlet should be a NEMA 6-20R and have the same
configuration as the plug. No adapter should be used with this product.
4
GROUNDING INSTRUCTIONS
The equipment must be grounded. If it should malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk of electric shock.
The unit is equipped with a cord having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances. If the user
does not follow these grounding instructions, the user could void the limited warranty.
ADDITIONAL ELECTRICAL INFO
In addition to the dedicated circuit requirement, the proper gauge wire must be used
from the circuit breaker box, to each outlet that will have the maximum number of
units running off of it. If the distance from the circuit breaker box to each outlet, is 100
ft (30.5 m) or less, then 12 gauge wire should be used. For distances greater than 100
ft (30.5 m) from the circuit breaker box to the outlet, a 10 gauge wire should be used.
ENERGY SAVING / LOW-POWER MODE
All units are configured with the ability to enter into an energy saving / low-
power mode when the unit has not been in use for a specified period of
time. Additional time may be required to fully reactivate this unit once it has
entered the low-power mode. This energy saving feature may be enabled
or disabled from within the 'Manager Mode' or 'Engineering Mode.
WARNING!
Connect this exercise product to a properly grounded outlet only.
• Never operate product with a damaged cord or plug even if it is working properly.
Never operate any product if it appears damaged, or has been immersed
in water. Contact Customer Tech Support for replacement or repair.
Failure to follow these specifications can cause damage
to your product and can void the warranty:
• All video and power outlets must be functional the day of delivery
/ assembly of the product. The client is responsible for any
additional installation charges associated with return visits.
• Electrical supply may fluctuate in your area. To ensure stable
performance of the product, use the proper gauge wire.
DANGER!
Improper connection of the equipment-grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or serviceman if you are in doubt as to whether
the product is properly grounded. Do not modify the plug provided with the product.