ELECTRICAL REQUIREMENTS
For your safety and to ensure good treadmill performance,
the ground on this circuit must be non-looped. Please
refer to NEC article 210-21 and 210-23. Your Treadmill is
provided with a power cord with a plug listed below and
120 NEMA 5-20R
120 NEMA 5-20R
requires the listed outlet. Any alterations of this power
cord could void all warranties of this product.
North American power cord plugs shown. Depending on your country, the plug type may vary.
DEDICATED CIRCUIT AND ELECTRICAL INFO
All Vision units require the use of a 20 amp "dedicated circuit, " with a non-looped (isolated) neutral/ground, for the power
requirement. Quite simply this means that each outlet you plug into should not have anything else running on that same circuit.
The easiest way to verify this is to locate the main circuit breaker box, and turn off the breaker(s) one at a time. Once a breaker
has been turned off, the only thing that should not have power to it are the units in question. No lamps, vending machines, fans,
sound systems, or any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit must have an individual neutral/ground connection coming from
it, and terminating at an approved earth ground. You cannot "jumper" a single neutral/ground from one circuit to the next.
In addition to the dedicated circuit requirement, the proper gauge wire must be used from the circuit breaker box, to each outlet
that will have the maximum number of units running off of it. If the distance from the circuit breaker box, to each outlet, is 100
ft or less, then 12 gauge wire may be used. For any distance greater than 100 ft from the circuit breaker box to the outlet, 10
gauge wire must be used.
6