1. Before starting the test :
(a) The circuit under test must be completely de-energized.
Check the fuse before testing.
Connecting to an energized circuit while the test is active will
blow the fuse.
See Testing the fuse later in this manual.
If the detected voltage is above 2V, ">2V" will appear on the
display.
In this condition, the test is inhibited.
(b) Short the test leads before measurement, and press the blue
button to compensate the probe resistance for <2Ω.
2. Lock mode : Press the Lock button to enter the Lock Mode.
Then press the TEST button to start the test. The test voltage will
continue to be applied until the TEST/LOCK button is pressed again.
3. The meter displays the ">" symbol and the maximum resistance for
the range when measured resistance is higher than the maximum
display range.