Before you call for service
Problem
Excessive/high
level of water in
brine tank
Salty tasting or
brown/yellow
colored water
after installation
Brown/yellow
colored water
Resin beads
showing up in
drinking water
Sounds you
might hear
Water has air
bubbles and is
cloudy
Blue light
flashing when
power applied to
the system
If "DAYS TO
EMPTY" is
flashing
Possible Cause
Valve drain hose pinched,
plugged, elevated too high or
otherwise restricted
Drain lines connected together
Nozzle and venturi dirty,
incorrectly assembled or
damaged.
Unit not sanitized
Low water pressure
Restricted drain hose
Unit was idle for a period of time
Cracked distributor or unit
plumbed backwards
Running water from the unit into
a drain during recharge
Air in system after installation
Control needs to be programmed
(a power outage may have
occurred)
Low salt level, less than 15 days
What to do
• A restriction in this drain hose may prevent
proper operation of the nozzle and venturi and
reduce or prevent brine draw during recharge.
• Separate drain lines.
• Refer to Cleaning the Nozzle and Venturi
Assembly instructions. With water pressure to
the water softening system off, take the nozzle
assembly apart. Inspect, clean and replace as
needed. Any foreign particle(s), scratches, nicks,
etc. in the passages can prevent operation. Be
sure holes in the gasket are centered over holes
in the housing
• Complete Sanitization Procedures.
• At completion of recharge cycle (approx. 2
hours), run water from faucets to purge the salty
water.
Check pressure:
• Drain height 8' or less, pressure should be
minimum 20 psi.
• Drain height above 8', pressure should be
minimum 50 psi.
• Clean and reconnect hose.
• Check for kinks in drain line
• Complete the Sanitization Procedures.
• Check softener "IN & OUT" plumbing is correct.
• Call for service.
• This is normal.
• Will go away after it runs for a while.
• See the Programming the Control section.
• Fill with salt.
• Reset salt level.