over the water tray (see page 5). Do not pour the liquid into the water
tray from high above the tray! Be sure that no liquid enters the air outlet
opening (26). This will damage the appliance and will void any claim to
the warranty.
• To start the cleaning mode, the mains cable must be connected to a sock-
et. Press and hold the night mode button (21) on the underside of the right
corner for 5 seconds to activate the cleaning mode. Now the water level
symbol (16) on the appliance will blink red. The cleaning mode runs for
around 5 minutes and automatically turns off afterwards (the water level
symbol stops blinking).
• Check in the water tray (9) if the limescale on the ultrasonic membrane
(19) and the heating plate (17) has dissolved. Attention: the water and the
heating plate are hot, risk of scalding!
• If limescale residue remains, the ultrasonic membrane (19) and the heat-
ing plate (17) can be cleaned with the help of the cleaning brush (25)
(front- and backside). Do not try to scrape them with a hard object.
• For stubborn limescale, we recommend descaling the appliance by run-
ning the cleaning mode (21) several times in a row. Leave the descaling
agent in the water tray for a maximum of 20 minutes and pour it out after-
wards as described below.
• Important: Pour the descaling agent out over the left front corner of the
appliance (see the arrow on the appliance). No water may enter the air
outlet opening (26). This will damage the appliance and will void any claim
to the warranty.
• To rinse, now fill the cup with 200 ml of tap water and carefully pour the
liquid into the water tray (9) by holding the cup directly over the water tray
(see page 5). Do not pour the liquid into the water tray from high above
the tray! Pour the water out over the left front corner of the appliance.
Repeat the process until there is no more descaling agent in the water
tray (9). Place the Silver Cube (24), cover (18), mist chamber (23), water
tank (6) and fragrance container (20) back into the appliance. If the water
tank is not sitting right, check if the upper part of the mist chamber (23)
is properly mounted.
• Clean the water tank (6) thoroughly every two weeks with a soft brush or
sponge and warm water. Use diluted descaling agent (mix according to
the manufacturer's instructions) for lime deposits. Rinse the water tank
afterwards with clean, cold tap water thoroughly.
Replacement of the anticalc cartridge
• Please find the recommended replacement interval in the table (see "Be-
fore setup").
• Tip: the efficiency of the cartridge (8) can be inspected with a simple test.
Hold a small mirror in the mist (27) for a few seconds. If white deposits
(calcium carbonate) appear on the mirror, then the cartridge needs chang-
ing.
• The anticalc cartridge is located on the inner side of the tank lid (7). First,
screw the tank lid (7) off the water tank (6) and then screw the cartridge
off the tank lid. Dispose of the cartridge in the domestic waste (8). Prior to
screwing the new anticalc cartridge into the inside of the tank lid, soak it
in water (not in the water tank!) for 24 hours.
• Keep the tank lid (7) when replacing the cartridge!