Range of blood pressure values Systolic (in mmHg) Diastolic (in mmHg) Measure
Grade 3: Severe hypertension
Grade 2: Moderate hypertension 160 – 179
Grade 1: Mild hypertension
High­normal
Normal
Optimal
Source: WHO, 1999
sure as well as the value above which your blood pressure is
classified as dangerous. The bar graph in the display and the
scale on the unit indicate the range of the blood pressure which
has been recorded.
If the values for systolic and diastolic pressure are in two dif­
ferent WHO ranges (e.g. systolic in the high­normal range and
diastolic pressure in the normal range) the graphic WHO clas­
sification on the unit indicates the higher range (high­normal in
the example described).

6. Saving, retrieving and deleting results

• The results of each successful measurement are stored
together with date and time. With more than 60 items of
measured data, the earliest items of data measured are lost.
• In order to retrieve measurement results again, press the
memory button M. First the average value of all saved meas­
urements of this user memory is displayed (Display ). If you
continue pressing the memory button M, what are in each
case the last results measured are displayed and audibly
announced with graphic WHO classification. You can adjust
All manuals and user guides at all-guides.com
> = 180
> = 110
100 – 109
140 – 159
90 – 99
130 – 139
85 – 89
120 – 129
80 – 84
< 120
< 80
Seek medical advice
Seek medical advice
Have it checked regularly by doctor yellow
Have it checked regularly by doctor green
Check it yourself
Check it yourself
the volume during the announcement by pressing the volume
key + and -.
• You can clear the memory by pressing and holding + and -
simultaneously for 5 seconds after pressing the memory but­
ton M and selecting the user.
• If you wish to change the user memory, see "Select mem­
ory".

7. Cleaning and storing the instrument

• Clean your device and cuff carefully only with a slightly mois­
tened cloth.
• Do not use detergents or solvents.
• On no account must you immerse the computer in water,
otherwise liquid can enter it and cause demage.
• When storing the device, make sure that no heavy objects
are placed on top of it. Remove the batteries. The cuff tube
should not have any sharp kinks.

8. Error messages / troubleshooting

In case of faults, the
Error messages can occur when
20
LeD is lightning
red
orange
green
green
message appears in the display.