ing. This helps to avoid tripping over the cord while
working.
e) When grinding with straight grinding discs and
cutting with cutting discs in metalworking appli-
cations, use the guard with cover plate.
f)
Always hold the power tool securely with both
hands on the grips provided. Keep the grips dry,
clean and free from oil and grease.
5.7.2 Power tool use and care
a) Grinding discs must be stored and handled care-
fully in accordance with the manufacturer's in-
structions.
b) Check that the grinding disc is fitted in accor-
dance with the manufacturer's instructions.
c) If use of a spacer ring or other intermediate part is
specified and the part is supplied with the grinding
disc, check to ensure that the part is fitted.
d) Never use the power tool without the guard.
e) The workpiece must be fixed securely in place.
After disc breakage, or if the power tool is
f)
dropped,
falls or suffers other mechanical
damage, it must be checked at a Hilti Service
Center.
g) Before use, check that the cutting or grinding
disc has been fitted correctly and the clamping
nut tightened. Then allow the power tool to run
for 30 seconds under no load while holding it se-
curely. Switch off the power tool immediately if
significant vibration or any other faults are no-
ticed. Should this occur, examine the power tool
in order to determine the cause.
h) Do not use cutting discs for grinding.
Do not use type 27 grinding discs with integrated
i)
clamping nut.
j)
Take steps to ensure that flying sparks from the
power tool do not present a hazard, i.e. by striking
yourself or other persons. Adjust the position of
the guard accordingly.
k) Children must be instructed not to play with the
power tool.
The power tool is not intended for use by children,
l)
by debilitated persons or those who have received
no instruction or training.
m) Do not use the power tool if it starts with a jolt.This
may be an indication that the electronic control unit
is defective. Have the tool repaired at an authorized
Hilti service center right away.
n) WARNING: Some dust created by grinding, sand-
ing, cutting and drilling contains chemicals known
to cause cancer, birth defects, infertility or other
reproductive harm; or serious and permanent res-
piratory or other injury. Some examples of these
chemicals are: lead from lead-based paints, crys-
talline silica from bricks, concrete and other masonry
products and natural stone, arsenic and chromium
from chemically-treated lumber. Your risk from these
exposures varies, depending on how often you do
this type of work. To reduce exposure to these
chemicals, the operator and bystanders should
work in a well-ventilated area, work with ap-
proved safety equipment, such as respiratory pro-
tection appropriate for the type of dust generated,
and designed to filter out microscopic particles
and direct dust away from the face and body.
Avoid prolonged contact with dust. Wear protec-
tive clothing and wash exposed areas with soap
and water. Allowing dust to get into your mouth,
eyes, or to remain on your skin may promote absorp-
tion of harmful chemicals.
5.7.3 Electrical safety
a) Before beginning work, check the working area
(e.g. using a metal detector) to ensure that no
concealed electric cables or gas and water pipes
are present. External metal parts of the power tool
may become live, for example, when an electric cable
is damaged accidentally. This presents a serious risk
of electric shock.
b) Check the power tool's supply cord at regular
intervals and have it replaced by a qualified spe-
cialist if found to be damaged. If the power tool's
supply cord is damaged it must be replaced with
a specially-prepared supply cord available from
Hilti Customer Service. Check extension cords
at regular intervals and replace them if found to
be damaged. Do not touch the supply cord or
extension cord if it is damaged while working.
Disconnect the supply cord plug from the power
outlet. Damaged supply cords or extension cords
present a risk of electric shock.
c) Dirty or dusty power tools which have been used
frequently for work on conductive materials
should be checked at regular intervals at a Hilti
Service Center. Under unfavorable circumstances,
dampness or dust adhering to the surface of
the power tool, especially dust from conductive
materials, may present a risk of electric shock.
d) When working outdoors with an electric tool
check to ensure that the tool is connected to the
electric supply by way of a ground fault circuit
interrupter (GFCI) with a rating of max. 30 mA
(tripping current). Use of a ground fault circuit
interrupter reduces the risk of electric shock.
e) Use of a ground fault circuit interrupter (GFCI)
with a maximum tripping current of 30 mA is
recommended.

5.7.4 Work area

a) Ensure that the workplace is well lit.
b) Ensure that the workplace is well ventilated. Ex-
posure to dust at a poorly ventilated workplace may
result in damage to the health.
en