Status Folder - Ingersoll Rand R37-160 Información Del Producto

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

60313.16.03
EN
Table 20: Ethernet Settings
Display Text
Enable Ethernet
Enable DHCP
IP Address Setting
IP Address Actual
MAC Address
Subnet Mask Setting
Subnet Mask Actual
Default Gateway Setting Setpoint for the default gateway.
Default Gateway Actual
Accept
Cancel

Status folder

All information on these pages is read only .
Pages 1-3: Analog Inputs
Figure 50: Analog Inputs
The following inputs are displayed in this section:
Package Discharge Pressure
Sump Pressure
Airend Discharge Temperature
Injected Coolant Temperature
Aftercooler Discharge Temperature
Separator Pressure Drop
Coolant Filter Pressure Drop
Inlet Vacuum
Aftercooler Discharge Pressure (integrated dryer compressors only)
Remote Pressure (optional)
Coolant Filter Inlet Pressure
Coolant Filter Outlet Pressure
Interstage Pressure (2-stage compressors only)
80446339 Rev C
All manuals and user guides at all-guides.com
Description
Allow connection by users to utilize the
network enabled functionality of the controller
Allow the controller to automatically receive an
IP address from the Local Area Network (LAN)
When DHCP is not enabled, this setpoint sets
the IP address of the controller.
This will match the IP address setting when
DHCP is not enabled. If DHCP is enabled
this will display the address assigned to the
controller by the DHCP server.
This is the unique hardware MAC address for
the controller. This can not be changed.
Setpoint for the subnet mask
Current reading/setting for the subnet mask
Current reading/setting for the default gateway.
After editing the desired setpoint navigate
to the accept setting and press enter in order
for the values in the setting variables to be
confirmed by the controller.
Discard any changes made to the Ethernet
settings.
NOTICE
Evaporator
Condenser
Page 4: Compressor Data
Figure 51: Compressor Data
The following data are displayed in this section:
Power On Hours
Running Hours
Loaded Hours
Real Time Clock
Pages 5-6: Digital Inputs
Figure 52: Digital Inputs
A marked checkbox beside a digital input indicates that the input is in its
TRUE state. For example, Starter Feedback is TRUE when its input is in the
high state, where as, E-Stop is TRUE when its input is at 0Vdc.
Emergency Stop
Main Motor Overload
Fan Motor Overload
Condensate Drain Error
Remote Stop
Remote Start
Remote Lead/Lag
Remote Load Enable
Remote Load/Unload
Auxiliary Input 1
Auxiliary Input 2
Dryer High Pressure
EN-8