12
TECHNICAL DATA
12
Technical data
Sensing range max.
Light spot size / distance
Supply voltage U
B
Ripple
Current consumption
Output current I
max.
Max. response time
Switching frequency
Enclosure rating
5)
Protection class
en
Circuit protection
Ambient temperature, operation
1)
16 VDC to 30 VDC, without load
10 VDC to 16 VDC, without load
2)
3)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
4)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
5)
Pursuant to EN 60529
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
7)
A = U
-Anschlüsse verpolsicher
B
B = Ein- und Ausgänge verpolsicher
C = Störimpulsunterdrückung
D = Ausgänge überstrom- und kurzschlussfest
8)
Do not bend cables below 0°C.
12.1
Dimensional drawings
32
O P E R A T I N G I N S T R U C T I O N S | WSE16
4.1
20
(0.79)
20
(0.79)
1
7.8
(0.31)
2
4
Ø 12.9
Ø 12.9
7.7
(0.51)
(0.51)
(0.3)
Figure 15: Dimensional drawing 1, cable
Center of optical axis, sender
1
Center of optical axis, receiver
2
Fixing hole Ø 4,1 mm
3
Connection
4
Display and setting elements
5
WSE16P
0 m ... 45 m
Ø 90 mm (8 m)
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
1)
< 50 mA
2)
≤ 100 mA
500 µs
3)
1,000 Hz
4)
see table
9:
x4, xH, x5, xI: IP66,
IP67, IP69
6)
x9, xB: IP65
III
A, B, C, D
7)
–40 °C ... +60 °C
42
(1.65)
20
(0.79)
(0.16)
5
29.9
(0.18)
1
35.5
(1.4)
6
3
(0.24)
6.5
(0.26)
3
(0.12)
15
(0.59)
27.8
(1.09)
M12
Figure 16: Dimensional drawing 2, male
connector
WSE16I
0 m ... 45 m
Ø 110 mm (8 m)
DC 10 ... 30 V
≤ 5 V
SS
≤ 30 mA
1)
< 50 mA
2)
≤ 100 mA
500 µs
3)
1,000 Hz
4)
see table
9:
x4, xH, x5, xI: IP66,
IP67, IP69
6)
x9, xB: IP65
III
A, B, C, D
7)
8)
–40 °C ... +60 °C
8)
42
(1.65)
20
(0.79)
4.1
(0.16)
5
29.9
(0.18)
52.9
(2.08)
2
17.5
6
(0.24)
(0.24)
3
4
3
(0.12)
15
15
7.5
M12
28
(0.3)
(1.1)
35.5
(1.4)
8020353.1DS6/2021-11-24 | SICK
Subject to change without notice
6.5
(0.26)
(0.59)