Selection Counter; General Counter; Enable Progr; Dose Setting - Rancilio classe 10 SDE Manual Para El Técnico

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
4.2.2

Selection counter

This displays the counters for each coffee group,
the water group, the TSC group and the total of the
counters. It also asks you whether you wish to reset
the counters or not. Even if you reset these counters,
the totals continue to increase.
4.2.3

General counter

This displays the counters for each coffee group,
the water group, the TSC group and the total of the
counters. It also asks you whether you wish to reset
the counters or not.

4.2.4 Enable progr.

Enabling or deactivating the doses scheduling it is
possible to release or inhibit the scheduling of the
doses by self learning.

4.2.5 Dose setting

Displays the impulses and the pre-brewing times for
each coffee and the hot water dispensing times for
each button of each group.
To change the doses and the pre-brewing times, use
the "+" and "-"buttons.
Dose programming can be carried out in the self-
learning mode as explained in the INSTRUCTION
and MAINTENANCE manual.
4.2.6

Delivery control

It is possible to activate one of the following func-
tions:
- "Disabled"
- Function "1"
Displays the dispensing time of each coffee at the
end of dispensing for a certain amount of time
e.g.
Gr1
27
- Function "2"
During the phases of dose programming, through
self-learning or the first time the dispenser is used
after changing the dose, the machine stores each
dispensing time.
This time is checked during dispensing and the
following will be displayed for a certain amount of
time at the end of the operation:
-"O.K." if the dispensing is within a range of +/-
10%
-The deviation in seconds if it exceeds the tole-
rated amount.
e.g.
Gr1
+5
If dispensing is selected with the start/stop button,
no indication is given
e.g.
Gr 1
. . .
4.2.7

Softener regeneration

From the "Internat. Settings" sub-menu you can
select the units of measure to be considered for the
supply water hardness and for the resin capacity
contained in the softener (French degrees-litres or
grains /gallons-grains).
Once the unit of measure has been set, these two
All manuals and user guides at all-guides.com
parameters can be defined in the "Values" sub-menu
by enabling the warning function to carry out the
regeneration of the softener resins.
To disable this function, set these values to "0".

4.2.8 Probe calibrate

Visualizes the presence and settings of:
- Temperature sensor
- Pressure transducer
4.2.9
Pressure setting
Set the pressure values of the boiler with 0.05 bar
increments.

4.2.10 International setting

Choose the international units to be used for the pres-
sure and the temperature (bar/P.S.I. and °C /°F).
4.2.11 Diagnostic
This programme enables you to select the different
devices and activate them to check their working
order or to check whether the CPU input and output
signals are being sent correctly.
To use the diagnostics, proceed as follows:
Press "enter" and, then using the "+" and "-" buttons,
choose the type of diagnosis.
The following can be chosen:
- Test Outputs
You can activate the panel LEDs and all the devices
(solenoid valves, pump etc.) as follows:
Press "enter" and, then using the "+" and "-" buttons,
choose what to check. Once you have selected the
output, activate it by pressing "enter".
- Test Digital Inputs
You can display the exact working order of the diffe-
rent panel buttons as follows:
Press "enter" and, then using the "+" and "-" buttons,
choose what to check. Once you have selected the
button press it to display the ON/OFF status.
- Test Analogue Inputs
The display will show the read value of the tempe-
rature sensors.
- Test Water Level
The display will show the status of the water level in
the boiler.
- Test Buzzer
This checks the working order of the buzzer of the
electronic data sheet.
47

Publicidad

Tabla de contenido
loading

Tabla de contenido