Electrical Specifications
Accuracy is ± (%reading + number of digits) at 23˚C ± 5˚C, with less than 75% R.H.
(1) AC Voltage: Auto-ranging
Range
400V
600V
* AC Conversion Type: AC Conversions are ac-coupled, true rms responding,
calibrated to the rms valve sine wave input, the basic accuracy is for sine wave at
full scale, for non-sine wave accuracy reference to * * .
** Crest Factor: 1.4 to 2.0, add 0.6% to Accuracy.
2.0 to 2.5, add 2.0% to Accuracy.
Input impedance: 10M Ω // less than 100 PF.
(2) AC Current: Auto-ranging
Range
Resolution
400A
600A
* AC Conversion Type: AC Conversions are ac-coupled, true rms responding,
calibrated to the rms value sine wave input, the basic accuracy is for sine wave at
full scale, for non-sine wave accuracy refer to * * .
** Crest Factor: 1.4 to 2.0, add 1.0% to Accuracy.
2.0 to 2.5, add 2.5% to Accuracy.
(3) Resistance: Auto-ranging
Range
Resolution
4K Ω
1 Ω
40K Ω
10 Ω
8
All manuals and user guides at all-guides.com
Resolution
100mV
1V
± (1.9%rdg + 5dgt) 50/60 Hz
0.1A
± (2.9%rdg + 5dgt) 50/60 Hz
1A
Accuracy*
± (2.0%rdg + 9dgt)
Accuracy*
± (1.2%rdg + 5dgt)
40 Hz ~ 500Hz
Accuracy*
Max. Open
Circuit Voltage
1V
Overload
Protection
600V rms
Overload
Protection
800V
Overload
Protection
600V rms