follows from page 30
- B -
SETTING MICROSWITCHES
DIP 1 MOTOR DIRECTION CHECK (ON) (POINT C)
DIP 2 TIME PROGRAMMING (ON) (POINT D)
O
PERATING MICROSWITCHES
(ON)
(OFF)
(ON)
(ON)
(ON)
(ON)
(ON-operated)
(ON- operated)
(OFF)
L
ED SIGNALS
T
ORQUE - ELECTRONIC TORQUE REGULATOR
L
OW SPEED – SPEED ADJUSTMENT DURING DECELERATION
E
LECTRONIC BRAKE (suggested operation)
G
RADUAL START (suggested operation)
(ON)
(OFF)
(OFF)
(ON - operated)
(OFF)
(ON)
- C -
MOTOR DIRECTION CHECK
After you have ensured the correct positioning of the limit
switch plates,
Put DIP 1 to the ON position
DL7 "CLOSE" turns on and the gate starts closing
"OPEN" turns on and the gate opens until it reaches the limit
switch for opening position;
5 - After 2 sec. and within 10 sec. of continuous work, both in
closing or opening, the electronic clutch intervenes
automatically. Adjust the force of the clutch by turning the
appropriate trimmer "TORQUE".
6 - After 10 sec. of continuous work, both in opening and closing,
the automatic deceleration is activated (if DIP 9 is on ON
position) Adjust the speed of the operator requested during the
deceleration by turning the appropriate trimmer "LOW SPEED".
At the end of the control, and of the trimmers adjustement,
position DIP1 to the OFF position.
- D -
TIME PROGRAMMING
PROGRAMMING WITH ENCODER (K PLUS)
WHEN THE TIME PROGRAMMING IS COMPLETED, MOVE DIP
2 TO THE OFF POSITION.
PROGRAMMING WITHOUT ENCODER (K)
NB: DIP7 SHALL BE TO THE OFF POSITION!!
NOTE:
The LED DL5 starts blinking
THE RED LED
THE GREEN LED DL6
G G
B B