Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B
follows from page 33
S
AFETY EDGE IN OPENING (11-12)
When the safety edge is not in used, the contacts 11-
12 must be bridged.
NB: from modification SW.07 on cards KS and KS Super,
operation of fence is as follows:
- during opening stroke, if resistance is encountered, motion is
reversed to close;
- during closure stroke, if resistance is encountered; motion is
reversed to opening
- in case resistance load persists, a further inversion is initiated
after 2 seconds, followed by a third short inversion and thus
signalling an alarm for fence failure or jamming (contact NO).
- in case the fence remains blocked (contact NO), no further
motion is allowed.
P
HOTOCELL 2 (9-12)
must be bridged.
C
OURTESY LIGHT (7-8)
T
RAFFIC LIGHT CONTROL
C
EXPANDER PLEX
ARTE
Code ACG5472
APPLICABLE ONLY TO CARDS KS AND KS SUPER WITH
SOFTWARE REV 07 OR LATER
couples
If it is not used, the contacts 9-12
allows the control of up to 4 photocells

MAIN FUNCTIONS

HEATER
CARD
Cod. ACQ9092 230V - Cod. ACQ9093 120V
R
ADIO TRANSMITTER MOON
ACG6082 - MOON 433
ACG7026 - MOON 91
C
ODE LEARNIG SYSTEM RADIORECEIVERS
ACG6081 - MOON 433
ACG7025 - MOON 91

Publicidad

Tabla de contenido
loading

Tabla de contenido