7W186eb1.fm Page 14 Monday, October 28, 2002 4:37 PM
If you select a USB device as the first boot device in the System Setup program, do not
remove the USB device until the server module has completed the boot process. If you
remove the USB device before the server module has booted, the system locks up because it
is still looking for the USB device. This will be corrected in a future BIOS release.
Using the System Diagnostics
•
•
Using the System Management Module to
Manage the Server Modules
If both of the system's power supplies are turned off, do not use the system management
module to manage the server modules. The Web console, serial interface, and Racadm
utility allow you to attempt to power on a server module even through both power supplies
are turned off. Also, the Web console reports that the power state for the power supplies
and fans is on. This will be corrected in a future firmware release.
When both of the system's power supplies are turned off, the system management module
reports that the power supplies have failed, and the system status indicator flashes amber.
System Management Module Time Issues
Web Console Displaying Incorrect Date/Time
If you logged into the system management module Web console and changed the time by
sending a setractime command using the serial interface or the Racadm utility, the next
time the Web console updates the Properties - Chassis Summary window, the login date
and time fields display incorrect data.
1-14
Infor mation and Fir mware Update
All manuals and user guides at all-guides.com
NOTICE: If you are using the USB CD drive as the boot drive, you must use the Dell
OpenManage Server Assistant CD that came with your system as the bootable CD. Using a DOS
bootable CD created with CD burner software packages causes a non-system disk failure.
When running the system diagnostics, the chassis service tag is displayed at the top of
the screen instead of the server module service tag. This will be corrected in a future
diagnostics release.
When running the video diagnostics test from a remote terminal, the remote keyboard
functionality is lost. To regain use of the remote keyboard, restart the HyperTerminal
session.