Dell 1655MC Manual Del Usuario página 20

Ocultar thumbs Ver también para 1655MC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 140
7W186eb1.fm Page 16 Monday, October 28, 2002 4:37 PM
5
6
7
8
9
10
Replacing Hard Drives in a Mirrored Configuration
If you replace a hard drive in a mirrored configuration and the new hard drive does not
automatically resynchronize, perform the following steps:
1
2
3
4
5
6
Online Diagnostics SCSI Controller Test Issue
When Using a Linux Console
When you run the online diagnostics SCSI controller test from a Linux console, the LSI
driver for the SCSI controller sends a SCSI error report to the screen. This is for
information only and does not indicate an error. If there were an actual error, the operating
system would report an error.
1-16
Infor mation and Fir mware Update
All manuals and user guides at all-guides.com
Press <Print Screen> to display the OSCAR menu, and then double-click the
appropriate server module.
Press <F2> to enter the System Setup program, and select the Boot Sequence option.
Ensure that the USB diskette drive is first in the boot sequence.
Save the changes and exit the System Setup program.
Reboot the server module to run the system board replacement utility.
When prompted, press any key to recreate the mirror and reboot the server module.
Remove the USB diskette drive.
Remove the faulty hard drive.
Install the server module in the system without the new hard drive installed.
Turn on the server module.
This allows the firmware to detect that the hard drive was removed.
Turn off the server module and install the new hard drive.
Install the server module in the system.
Turn on the server module.
During POST, the following message displays:
Logical Drive is Degraded
At this point, the hard drive begins to resynchronize.