Before Initial Operation

Charge Battery

Battery pack is supplied partly charged and must be
charged completely being used for the first time.
► See Original Instructions of Milwaukee charger.
► Do not use any other battery packs / chargers than
the following:
Battery pack 18 V
Order no.
Capacity
T50-1000497
2,0 Ah
T50-1000498
5,0 Ah
Charger 18 V
Order no.
Country
T50-1000499
North America
T50-1000506
Europe
T50-1000507
Brazil
T50-1000543
Argentina
T50-1000544
United Kingdom
T50-1000545
China
3
Use of 80 % of maximum torque
Apex Tool Group
Sound
Meaning
Tool overheat-
ing

Maintenance

alarm
Battery low sta-
tus
General error
1-Bay
P2547BA | 2021-08
Order no.
Country
T50-1000546
Japan
T50-1000500
North America
T50-1000508
Europe
T50-1000547
United Kingdom

Setting the torque

Caution
Winding hazard
Unintentional start-up can cause the output
to start up and cause serious finger injuries.
► Disconnect the tool from the power sup-
ply when converting work.
► Using the clutch adjustment tool provided:
turn clockwise for maximum torque.
turn counterclockwise for minimum torque.
Fig. 1-2: Setting the torque
Recommendation: For best results, start from
minimum torque and adjust in the maximum di-
rection until desired torque is achieved.
7
Maintenance
Note
Loss of warranty
Repairs are only permitted by Apex Tool
Group authorized personnel. If the tool is
opened, the warranty is voided.
► If repair is required send the complete
tool to Sales & Service Center!
Maintenance
Measures
after every ...
cycles
3
Daily
► Check all connections.
► Visual inspection for general dam-
age.
► Perform a general function test
and watch out for excessive vibra-
tion or unusual noise.
250,000
► Send the tool to a certified Sales &
Service Center for assessment.
1