1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
None
Check the version and code of machine
1 time
GAS TYPE: P2:Og
2 time
PDA CHECK
3 time
Drum Motor runs
4 time
Blower Motor runs
GAS TYPE: GAS valve runs
Drum Motor + Blower Moror + Valve
5 time
LED & KEY CHECK
Press High Temp. button
6 time
Press Med Temp. button
Press Low Temp. button
Press No Heat button
7 time
Test ends.
Door switch
(Drum Motor & Blower Motor &
During check, if the
Heater Off, Buzzer seven times)
Door or LintFilter is
LintFilter switch
open
(Drum Motor & Blower Motor &
Heater Off, Buzzer seven times)
During check, if the
Test goes back at step 3
Door and LintFilter
(Drum Motor on & Blower Motor off &
is closed
Heater off )
NOTE
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
All manuals and user guides at all-guides.com
Checking point
PROGRAMMING MODE
Display
LqC 1
Version and code of machine(All LED on)
Display P2:Og, tu:XX, td:XX and tS:XX
alternately. XX is the version number
Ir--
Measured moisture value (70~239)
Blower Motor RPM (~3000)
Display the blower motor RPM and the temperature
inside the drum in Celsius alternately
1.Blower Motor RPM (~3000)
2.Current temperature (5~70)
Version and code of machine
LqC1
dE (the door or lint filter is open. Please close the door
and lint filter completely)
Measured moisture value (70~239)
43