PROgRAMMINg MODE - Collect Mode
Collect Information Data : ClCt (display)
The dryer collects the usage data so that the owner can check various information like number of various cycles
used, how many times card or coins used, etc.
Entering the collect mode
Data Name
Button
1. Entering the
programming mode.
2. High Temp.
Entering
3. low Temp.
the collect
mode
4. Start
5. med Temp. or low
Temp.
6. Start
Check the collect information reference to the follow lists. The Lists are displayed by abbreviations.
Collect mode Data lists
No.
Abbreviation
1
rgPr
Regular Price
2
rgCP
Regular Cold Price
3
rgrP
Regular Warm Price
4
rgHP
Regular Hot Price
5
dELC
Dryer Moisture Sense
6
ItrC
Interval Regular Cycles
7
ItCC
Interval Regular Cold Cycles
8
ItAC
Interval Regular Warm Cycles
9
ItHC
Interval Regular Hot Cycles
10
ItSC
Interval Super Cycles
11
IttF
Interval Topoff Cycles (Dryer Only)
12
ItUC
Interval Service Cycles
13
ItFC
Interval Token Cycles
14
ACrC
Accumulated Regular Cycles
15
ACCC
Accumulated Regular Cold Cycles
16
ACAC
Accumulated Regular Warm Cycles
17
ACHC
Accumulated Regular Hot Cycles
18
ACSC
Accumulated Super Cycles (Washer Only)
19
ACtF
Accumulated Topoff Cycles (Dryer Only)
20
ACUC
Accumulated Service Cycles
21
ACFC
Accumulated Token Cycles
22
ACrt
Accumulated Run Time
All manuals and user guides at all-guides.com
Display
Insert service card(card type), Turn on/off toggle switch
(Coin type).
Press the High Temp. button until "tESt" appears in the
display.
Press the Med Temp. or Low Temp. button until "CLCt"
appears in the display.
Enter the Collect information data.
Move to each data list that you want to check by pressing
with Med Temp. or Low Temp. button.
Display the value of selected data list
meaning
Description
Description
$ 0.00~ $ 9.95
rgCP is not available in dryer. (It can't enter.)
rgrP is not available in dryer. (It can't enter.)
rgHP is not available in dryer. (It can't enter.)
dELC is not available in dryer. (It can't enter.)
Number of Regular cycles ( 0~65535 )
ItCC is not available in dryer. (It can't enter.)
ItAC is not available in dryer. (It can't enter.)
ItHC is not available in dryer. (It can't enter.)
ItSC is not available in dryer. (It can't enter.)
Number of Topoff cycles ( 0~65535 )
Number of Service cycles (0~65535)
Number of Token cycles (0~65535)
Number of Regular cycles ( 0~65535 )
ACCC is not available in dryer. (It can't enter.)
ACAC is not available in dryer. (It can't enter.)
ACHC is not available in dryer. (It can't enter.)
ACSC is not available in dryer. (It can't enter.)
Number of Topoff cycles ( 0~65535 )
Number of Service cycles ( 0~65535 )
Number of Token cycles (0~65535)
Number of Running minutes ( 0~65535 )