apart with the cleaning solution. Carefully clean their
undersides.
4
In the same manner clean the evaporator cylinder(s) using
a soft bristle brush.
5
Rinse all cleaned parts with cool clean water.
5. 3. 3 SANITIZING
Sanitizing should be performed immediately prior to
starting the machine. Do not allow the unit to sit for
extended periods of time after sanitization.
1 - Wash hands with a suitable antibacterial soap.
1
Prepare at least two gallons of a warm (45-60 °C 120-
140 °F) sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with 2
litres of water) according to your local Health Codes and
manufacturer's specifications.
2
Place the parts in the sanitizing solution for five minutes.
3
Do not immerse the lighted top covers in liquid. Carefully
wash their undersides with the sanitizing solution.
4
Place the sanitized parts on a clean dry surface to air dry.
5
Wipe clean all exterior surfaces of the unit. Do not use
abrasive cleaner.
5. 3. 4 ASSEMBLY
1 - Slide the drip tray into place.
1
Lubricate faucet piston, inside auger and outer spiral (see
points A, B and C of figure 14) only with the grease supplied by
the manufacturer or other food grade approved lubricant.
2
Assemble the faucet by reversing the disassembly steps
(see figure 13)
3
Fit bowl gasket around its seat.
Note: the largest brim of gasket must face against the rear wall
(see figure 15).
4
Insert the auger into the evaporator taking care to
accompany it to the end so as to prevent it from hitting against
figure 14
figure 15
the rear wall (see figure 16).
5
Install the outer spiral. Slide it over the evaporator until its
front notch engages with the exposed end of the auger shaft
(see figure 17).
6
Push the bowl towards the rear wall of the unit until it fits
snugly around the gasket and its front fastening hooks are
properly engaged (see figure 18).
7
Use fresh product to chase any remaining sanitizer from the
bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the machine may
be performed, if needed, only as further precaution, in
9
figure 16
figure 17
figure 18