RIB K400 Manual Del Usuario página 33

Ocultar thumbs Ver también para K400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

by factory NOT ACTIVATED and LED DL11 OFF (trimmer fully rotated counterclockwise)
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic
closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11 ON
(trimmer rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a
maximum of 2 minutes.
The pause time (for gate open with PED. control) can be adjusted from a minimum of 2 s to a
maximum of 30 s.
Ex: With TCA trimmer setted halfway, you will have 1 minute pause after the total opening and 15
s of pause after the pedestrian opening prior to have the auto-close of the gate.
TRIMMER SENS - impact sensor regulator
By factory enabled and DL15 ON (trimmer halfway)
The L1 24V control board is equipped with an impact sensor that reverses the gate's travel if it
impacts on things or people (in compliance with the EN standards in force - always check with
a suitable instrument to comply with the values set by the EN12453 standard.
With impact in opening, it reverses the closing movement for 1 s and then stops.
With impact on closing, it reverses the opening movement for 1 s and then stops.
With this trimmer it is possible to adjust the impact reaction:
- with trimmer turned fully counter-clockwise and DL15 OFF, impact sensor deactivated.
- with trimmer at minimum, the impact reaction occurs after 3 s (low sensitivity)
- with trimmer at halfway, the impact reaction occurs after 1.5 s (medium sensitivity)
- with trimmer at max, the impact reaction occurs after 0,4 s (high sensitivity)
The movement will restart at a slow speed until the opening or closing limit switch is reached.
IMPACT SENSOR ALARM
The alarm status will be displayed by the flasher which will remain active for one minute and
the buzzer with 3 tones every 5 s. During this time, the gate can be reset by pressing any
control button.
R-AUX - AUXILIARY RELAY CONTACT (NO)
Normally this relay is set as courtesy light (max 700 W - 3 A - 230 Vac) to operate 3 minutes at
each command, with time renewed at each command.
You can activate the R-AUX contact by TRANSMITTER by performing the memorization
procedure described in point H and the RIB GATE App.
GRADUAL BRAKING
DIP 10 ON => Brake activated. With the RIB GATE app it is possible to regulate braking making
it gradual.
GRADUAL START
DIP 11 ON => gradual motion is enabled for 0,5 second with every start.
LED SIGNALS
DL1
programming signal enabled
DL2
opening gate signal
DL3
closing gate signal
DL4
opening limit switch signal
DL5
closing limit switch signal
DL6
STOP contact signal
DL7
photocell PHOTO 1 contact signal
DL8
photocell PHOTO 2 contact signal
DL9
EDGE 1 contact signal
DL10
EDGE 2 contact signal
DL11
TCA - automatic closure time enabled
DL12
Remotes programming enabled
DL13
Card managed by APP
DL14
encoder status signal
DL15
SENS - impact sensor enabled
DL16
manual unlock micro-switch signal
DL17
PROG commands
OPEN
OPEN command (NO)
CLOSE
CLOSE command (NO)
START
Single impulse command (NO)
PED.
Pedestrian command (NO)
B.I.O
Clock command (NO)
C – LIMIT SWITCH CAMS and SPEEDS ADJUSTMENTS
This control has the task of facilitating system commissioning or any subsequent adjustments
for the installer.
N.B. : During this control the safety functions Safety edge, Photocells, Stop button and Impact
sensor are NOT active.
1 - Unlock the operator using the manual release and position the limit switch cams on the rack,
so as to define the gate stroke.
2 - Bring the gate to mid-stroke position and lock the operator.
3 - Set DIP 1 to ON mode = > led DL1 starts flashing.
4 - Press and hold the PROG button (the command is operator-run, open-stop-close-stop-open-
etc...) = > the gate starts at high speed and then slows down until it reaches the limit stop.
Check that the gate stops in the desired position. If not, move the limit switch cams and try
again. Check the limit switch on the opposite side.
5 - You can adjust the high speed during the first 5 s of operation by rotating the RUN trimmer.
Rotating the RUN trimmer clockwise, the speed increases. The RUN trimmer is normally set
to max.
6 - It is possible to adjust the slow speed after the first 5 s from the start and for the rest of the
run by operating on the LOW SP trimmer. Turning the LOW SP trimmer clockwise increases
the speed. The LOW SP trimmer is factory set at half stroke.
7 - When done, reset DIP 1 to OFF. Led DL1 goes OFF signalling exit from the control.
IMPORTANT: During this operation, the stop button, edges and photocells are not enabled.
D – FULL OPENING PROGRAMMING
NB. : During the programming phase, the safety functions Safety edge, Photocells, Stop
button and Impact sensor are active and their performance level is PL "c" according
to EN13849-1. Their intervention stops the programming (led DL1 shifts from flashing
to on steady).
Caution: If the inputs STOP, PHOT 1, PHOT 2, EDGE 1 and EDGE 2 are not connected, run jumpers
between COM A+/STOP/PHOT 1/PHOT 2/EDGE 1/EDGE 2 before you proceed with
programming.
N.B. : In this case, the safety functions Safety edge, Photocells, Stop button are NOT active.
1 - IMPORTANT: TO PROPERLY PROGRAMME THE OPENING, YOU MUST POSITION THE GATE AT ABOUT
2 - Set DIP 2 to ON mode = > led DL1 starts flashing.
3 - Press the PROG button or the remote control button (if previously memorized) dedicated to
the total opening. The gate will begin a series of movements. DO NOT PASS IN FRONT OF THE
PHOTOCELLS WHILE THE GATE IS MOVING.
4 - The programming stops when the gate is closed and led DL1 is OFF.
5 - Set DIP 2 to OFF.
Note well: If at the end of the programming procedure the trimmer RUN is moved, the
Note: the low speed starting point is calculated automatically by the control unit during the
time programmin procedure. It will start 50 ÷ 60 cm before reaching the opening or
closing limit stop.
To repeat the programming procedure, position the DIP 2 in the OFF mode, and by using the
procedure "C – Adjust stroke in line with electrical or magnetic limit switches" close the gate
almost completely, leaving it open for 20 cm. Then, repeat the programming procedure as
described above.
(red)
E – PEDESTRIAN OPENING PROGRAMMING
(green)
NB. : During the programming phase, the safety functions Safety edge, Photocells, Stop
(red)
button and Impact sensor are active and their performance level is PL "c" according
(green)
to EN13849-1. Their intervention stops the programming (led DL1 shifts from flashing
(red)
to on steady).
(red)
When the gate is closed:
(red)
1 - First, set DIP 2 to ON and then DIP 1 to ON. Led DL1 starts flashing.
(red)
2 - Press the pedestrian button (COM A+/PED.) or the remote control button (if previously
(red)
memorized) dedicated to the pedestrian opening = > The gate opens.
(red)
3 - Press the pedestrian button to stop the gate (the pedestrian opening stroke of the gate is
(red)
now set). After 2 s the gate will automatically close..
(red/green)
4 - When done programming the pedestrian opening, set DIP 1 and DIP 2 to OFF.
(blu)
To repeat the programming procedure, position DIP 1 and DIP 2 to OFF and by using the
(red)
procedure "C – Adjust stroke in line with electrical or magnetic limit switches" close the gate
(red)
completely. Then, repeat the programming procedure as described above.
(red)
(green)
F - RADIO CODES PROGRAMMING PROCEDURE FOR TOTAL OPENING (1000 CODES
(green)
MAX) - with radio module ACG8069
(green)
(green)
ATTENTION: before storing the radio codes, use DIP 12 to select which transmitters to use:
(green)
DIP 12 OFF: SUN PRO variable code transmitters can be memorized:
(green)
SUN PRO 2CH 2-channel - red keys and white led cod. ACG6210
SUN PRO 4CH 4-channel - red keys and white led cod. ACG6214
DIP 12 ON (by factory): You can store transmitters with fixed code SUN:
SUN 2CH 2-channel - blue keys and white led cod. ACG6052
SUN 4CH 4-channel - blue keys and white led cod. ACG6054
SUN CLONE 2CH 2-channel - blue keys and yellow led cod. ACG6056
33
20 CM FROM THE CLOSING LIMIT-SWITCH.
programming procedure must be repeated.
G
B

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aa40928Aa40929L1 24v-crx

Tabla de contenido