Descargar Imprimir esta página

Victron energy BlueSolar MPPT 150/45-Tr Manual De Instrucciones página 5

Ocultar thumbs Ver también para BlueSolar MPPT 150/45-Tr:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1.8 Adaptive three step charging
The BlueSolar MPPT Charge Controller is conf igured f or a three
step charging process: Bulk – Absorption - Float.
A regular equalization charge can also be programmed: see
section 3.8 of this manual.
1.8.1. Bulk stage
During this stage the controller deliv ers as much charge current
as possible to rapidly recharge the batteries.
1.8.2. Absorption stage
When the battery v oltage reaches the absorption v oltage setting,
the controller switches to constant v oltage mode.
When only shallow discharges occur the absorption time is kept
short in order to prev ent ov ercharging of the battery . Af ter a deep
discharge the absorption time is automatically increased to make
sure that the battery is completely recharged. Additionally , the
absorption period is also ended when the charge current
decreases to less than 2 A.
1.8.3. Float stage
During this stage, f loat v oltage is applied to the battery to
maintain it in a f ully charged state.
1.9 Connectivity
See section 3.8 of this manual.
1.10 Remote on-off
VE.Direct non inv erting remote on-of f cable (ASS030550300)
needed. An input HIGH (Vi > 8V) will switch the controller on, and
an input LOW (V < 2V, or f ree f loating) will switch the controller
of f .
Application example: on/of f control by a VE.Bus BMS when
charging Li-ion batteries.
1.11 Real-tim e data display on Apple and Android
sm artphones, tablets and other devices
VE.Direct to Buetooth Low
Energy (BLE) dongle
needed: see our w ebsite.
2

Publicidad

loading