12.7 Electrical connection

In order to ensure the safe and trouble-free operation of the device, the following instructions
must be observed for the electrical connection:
 Before connecting the device, compare the connection data (voltage and frequency) on
the rating plate with those of your electrical network. This data must agree in order that
no damages occur in the device
If in doubt, ask your qualified electrician.
 The electrical outlet must be protected by a 16A safety cut-out switch.
 The connection between the device and the electrical network may employ a 3 meter long
(max.) extension cable with a cross-section of 1.5 mm². The use of multiple plugs or
gangs is prohibited because of the danger of fire that is involved with this.
 Make sure that the power cable is undamaged and has not been installed under the oven
or over hot or sharp surfaces.
 The electrical safety of the device is only guaranteed if the device is connected to a
properly installed protective conductor system. Operations using an electrical outlet
without a protective conductor are prohibited. If in doubt, have the house installation
checked over by a qualified electrician.
The manufacturer cannot be made responsible for damages that are caused by a
missing or damaged protective conductor.

13 Design and Function

This chapter provides you with important safety notices on the design and function of the
device.
The energy output is more constant due to the device's inverter technology, the energy
efficiency is higher due to this and the dishes are heated up more gently.