RECOMMENDED STOCK ITEMS

Refer to the Parts List section for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description. See example below:

TROUBLE SHOOTING

PROBLEM
No power, nothing runs.
Brush motor does not run.
Vacuum motor does not run.
Short run time.
Tennant 5540/5560 (08- -05)
CAUSE
Batteries need charging.
Faulty battery(s).
Loose battery cable.
Battery connection is improper.
Faulty Main switch
Main circuit breaker has tripped.
Brush circuit breakers have
tripped, or has been pulled out.
Control grips are not twisted.
Faulty brush motor or wiring.
Faulty brush switch.
Carbon brushes worn.
Faulty solenoid.
Vacuum circuit breaker has
tripped.
Faulty vacuum switch.
Faulty vacuum motor or wiring.
Faulty solenoid.
Carbon brushes worn.
Batteries not fully charged.
Bad cell in one or more batteries.
Batteries need maintenance.
Faulty charger.
Home Find... Go To..
OPERATION
SOLUTION
See CHARGING BATTERIES.
Replace battery(s).
Tighten loose cable.
See INSTALLING BATTERIES.
Contact Service Center.
Determine cause and reset circuit
breaker button.
Clean or change to a less aggres-
sive pad. Also, release brush
pressure lever if it's in the up posi-
tion. Reset breaker button.
Control grips must be twisted to
activate brushes.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Remove obstruction and reset
breaker.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Charge batteries.
Replace battery.
See BATTERY MAINTENANCE.
Replace battery charger.