OPERATION
CIRCUIT BREAKERS
The machine is equipped with (4) circuit breakers to
protect motors from damage. If circuit breakers trip,
they cannot be reset immediately. Determine reason
why breaker tripped, allow motor to cool and then
reset. Brush motor circuit breakers will trip due to
excessive overload on pad. Clean or change pad if
breaker should trip. Circuit breaker buttons are
located at rear of machine as shown (Figure 19).
-- 10A Main Circuit Breaker
-- 35A Drive Motor/Vacuum Circuit Breaker
-- 35A Brush Motor Circuit Breaker (2)
NOTE: When servicing machine or when machine is
left unattended, pull out the Main circuit breaker
button. This will shut off all power to machine.
DRAINING TANKS
The recovery tank should be drained and cleaned out
after every use. The solution tank should be cleaned
out periodically to remove any corrosion.
Transport the machine to a draining site, turn the key
off and follow the draining instructions below:
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
DRAINING RECOVERY TANK
1. Remove drain hose from holder, position hose
over floor drain and twist off drain hose cap. To
completely drain recovery tank, hinge open tank
and flip up tank support stand to rest tank on
(Figure 20).
12
FIG. 19
Home Find... Go To..
NOTE: If using a bucket to drain machine, do not use
same bucket for filling solution tank. This will prevent
possible solution line clogs.
FIG. 20
2. Rinse out recovery tank after each use. This will
prevent foul odor buildup. Use a hose to rinse out
the recovery tank. Be careful not to spray water
into shut--off float screen.
DRAINING SOLUTION TANK
1. Pull clear hose off hose barb at rear of machine
and drain solution into floor drain or bucket
(Figure 21).
FIG. 21
2. Rinse out solution tank with clean water after each
use and flush out solution flow system by pushing
solution flow lever forward. This will prevent
clogging due to chemical buildup. Use clear hose
to drain solution tank.
3. Reconnect clear hose to hose barb. Be certain
hose is completely pushed onto hose barb.
Tennant 5540/5560 (08- -05)