Press the hot water dispensing key (12). The following mes-
sage will appear on the display:
KEY MENU
Type
dispens. time
The following hot water selection parameters can be modi-
fied:
- water dispensing time (dispensing time in seconds.).
The water doses for coffee and the hot water doses can also
be set using the "SELF-SETTING' function:
press and hold the STOP button for at least 8 seconds or until
you hear a buzzer sound that will keep sounding throughout
the programing. The menu below will appear on the display,
showing the keys with the relative quantities for water for the
coffee.
SELF-LEARNING
Group 1
090
150
Coffee measures
1 - Fill the filter-holder with the required dosage of ground
coffee and insert it in the dispenser unit.
2 - Put the cup or container under the filter-holder spouts and
press the button to be programed. Keep it pressed until the
desired level is reached in the cup or container.
16.2 Key menu - Hot water selection
+
dosed
05.0
Programming measures using the "SELF-LEaRNING" function
DV:
000
STOP
080
160
12
During this phase, the setting for the volumetric dosage
pulses (top right of display) is increased. When the key is
released, the setting reached is memorized and appears
under the programmed key.
3 - Starting from step 1, continue programing, as desired, on
all the coffee buttons.
Hot water measures
1 - Press the button to be programed and keep it pressed until
the desired level is reached in the cup.
During this phase the time in seconds (top right of display)
is increased; when the key is released, the setting reached
is memorized and appears below the programmed key.
water buttons
3.5
2 - Starting from step 1, continue programing, as desired, on
all the water buttons.
When finished, press the STOP button. The buzzer will turn off,
thus confirming that the programing has been completed.
49
12
SELF-LEARNING
t: 3.5
STOP
5.0