Automatic Cleaning; Time-Dependent Cleaning; System Messages - Oase BioTec ScreenMatic2 40000 Instrucciones De Uso

Ocultar thumbs Ver también para BioTec ScreenMatic2 40000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
6.3

Automatic cleaning

Due to the build-up of debris the water level on the ScreenMatic screen also rises. When the sensor in the
control device comes into contact with the water, it triggers the rotational movement of the ScreenMatic
screen.
By briefly moving the ScreenMatic screen back several times a larger line of debris is formed, which can be
better removed by the stripper.
Sequence of an automatic cleaning cycle
Normal soiling
1.
Contact of the sensor with water
2.
Contact of the sensor with water
3.
Contact of the sensor with water
4.
Contact of the sensor with water
Heavy soiling or incorrectly aligned control device (perma-
nently high water level on the ScreenMatic screen)
1.
Contact of the sensor with water
6.4

Time-dependent cleaning

The ScreenMatic rotating screen unit executes a cleaning cycle after a set interval depending on the ambient
temperature. This ensures cleaning at regular intervals
• if the sensor is soiled or defective,
• if there is very little soiling on the screen and/or low flow rates (e.g. when the SFC of the filter pump is acti-
vated).
Ambient temperature
≤10 °C
10 °C ... 20 °C
≥20 °C
6.5

System messages

LED
Malfunction
Flashes
No automatic cleaning cy-
green/red
cle within 48 hours
No flow of water
No water detected by the
sensor
Flashes red
20 automatic cleaning cy-
cles in succession
Flashes green
ScreenMatic screen not ro-
tating although a manual
Interval
6 hours
4 hours
3 hours
Possible cause
Sensor soiled
No dirty water, cleaning is not
necessary
Filter pump is not operating
Control device incorrectly posi-
tioned
Control device defective
Insufficient conductivity of the
water
Insufficient pump capacity
ScreenMatic screen soiled
Sensor soiled
Control device incorrectly posi-
tioned
Pump capacity too high
Motor cable plug not connected
or incorrectly connected to the
control device
Rotational movement of the ScreenMatic screen
Brief movement backward
Brief movement backward
Brief movement backward
One rotation forward
• The debris is conveyed into the debris tray.
Brief movement backward, then one rotation for-
ward
• The debris is conveyed into the debris tray.
Rotational movement of the ScreenMatic screen
One rotation forward
• The debris is conveyed into the debris tray.
Remedy
• Clean the sensor.
• Descale the sensor.
Start up the filter pump.
Correctly position the control de-
vice
Replace the control device.
Increase the water hardness with
OptiPond
Adjust the pump capacity accord-
ingly
• Start manual the cleaning cycle
and use a brush to clean the
ScreenMatic screen on the side
of the water distributor
(→ Manual cleaning)
• Clean the ScreenMatic screen
from the inside if the mesh is
clogged by a biofilm
(→ Cleaning/replacing the
ScreenMatic screen)
Clean the sensor.
Correctly position the control de-
vice
Adjust the pump capacity accord-
ingly
Connect the plug, check that it is
correctly seated.
- EN -
Resetting the system
message
Automatic reset after rem-
edy of malfunction
Automatic reset after rem-
edy of malfunction