7. The interior marking on the device head must agree with the marking on
the housing (see fig.). Push the device head carefully into the housing
until the stop. Note: If the device head cannot be completely pushed on,
then check whether the clamp screw is screwed on until the stop.
8. Turn the device head in the opposite direction of the arrow using light
pressure until the stop (markings on the device head and housing point to
each other). The safety engaging lever must click to place.
9. First place the pump in service again, then plug the Bitron's power plug
into the power outlet (see chapter "Placing in service").

10.Cleaning

10.1 Automatic cleaning

The cleaning rotor is continuously guided around the quartz glass sleeve by
the water flow. This directly prevents sludge and slime from settling.
The result is a quartz glass sleeve that is always clear, which ensures 100%
efficiency of the irradiation.
The Bitron must be in permanent operation.
Intermittent operation can produce tough dirt and lime scale deposits that
must be removed through manual cleaning.
The rotary movement produces noise which increases as the water flow
increases. Remove the flow nozzle as needed.
10.2 Cleaning the quartz class sleeve
1. Unplug the Bitron's power plug.
2. Switch off the pump and safeguard it from being turned on again
unintentionally.
3. Press the safety engaging lever, turn the Bitron device head in the direction
of the arrow until the stop, and pull it out carefully with the cleaning rotor.
4. Pull the cleaning rotor off of the quartz glass sleeve and clean it thoroughly.
Likewise, thoroughly clean the housing inside and outside.
5. Clean glass sleeve with a damp cloth.
6. Push cleaning rotor onto the quartz glass sleeve (see fig.).
7. Check the O-ring on the device head for damage and correct seat. The
O-ring must sit in front of the recess on the device head (see fig.).
8. Push the device head carefully into the housing. The cleaning rotor and
the quartz glass sleeve will be pushed into the rear receptacle inside the
housing in this process.
9. The interior marking on the device head must agree with the marking on
the housing (see fig.). Push the device head carefully into the housing
until the stop. Note: If the device head cannot be completely pushed on,
then check whether the clamp screw is screwed on until the stop.
10. Turn the device head in the opposite direction of the arrow using light
pressure until the stop (markings on the device head and housing point to
each other). The safety engaging lever must click into place.
11. First place the pump in service again, then plug the Bitron's power plug
into the power outlet (see chapter "Placing in service").