Connecting A Uvc Clarifier; Connecting The Outlet; Connecting The Dirt Outlet; Carry Out The Electrical Connection - Oase BioTec ScreenMatic2 18000 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- EN -
3.3

Connecting a UVC clarifier

Prerequisite:
• The container is open. (→ Opening the container)
• The screen holder is hinged up. (→ Hinging the screen holder up/down)
How to proceed:
 K
1. Fit the UVC clarifier with flat seal into the inlet opening.
2. Screw the distributor nut with O ring onto the stepped hose adapter and hand tighten.
– Read the UVC clarifier operating instructions.
3.4

Connecting the outlet

• Use suitable pipes.
• Do not use any right-angled bends. Bends with a maximum angle of 45° are very efficient.
• Standing water in pipes can freeze when there is a hard frost and cause pipes to burst. For this reason, lay
the pipes and hoses with a gradient (50 mm/m) to ensure that they can run empty.
• Pipe dimensions: (→ Technical data)
Fitting the DN 110 outlet
BioTec ScreenMatic² 38000: The outlet is not fitted on delivery.
Prerequisite:
• The container is open. (→ Opening the container)
How to proceed:
 L
1. Fit the O ring onto the outlet.
2. Fit the outlet into the respective hole of the container wall from the outside.
– Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
3. Fasten the outlet from the inside with oval head screws.
– Tighten all screws diagonally using the cordless screwdriver to ensure that the sealing ring is uniformly
applied. Further tighten the screws using a Phillips screwdriver.
N O T E
Build supports to increase the stability of the pipe construction and to prevent the pipe construction
from sagging at the discharge.
3.5

Connecting the dirt outlet

The water in the container can be drained via the dirt outlet with slide valve at the bottom of the container
when required (for cleaning, repair, overwintering).
• Connect the pipe and drain the dirty water, for example, into a flower bed or into the sewage system.
• Pipe dimensions: (→ Technical data)
3.6

Carry out the electrical connection

How to proceed:
 M
1. Thread the connection cable through the opening in the container wall and seal off the opening using the
sealing plug.
– Ensure that the connection cable inside the container is sufficiently long so that it is not subjected to ten-
sion when the ScreenMatic rotating screen unit is hinged up.
– Avoid tangling of the cable inside the container.
2. Connect the plug of the connection cable to the socket on the transformer and hand-tighten the union nut.
18

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Biotec screenmatic2 24000Biotec screenmatic2 38000

Tabla de contenido