4.4 Chimney and flue pipe
The fireplace must only be connected to a chimney and
flue pipe approved for solid fuel fireplaces with flue gas
temperatures as specified in «2.0 Technical Data».
Several solid fuel stoves can be connected to the same
chimney system if the chimney cross section is adequate.
NB: Look into the applicable rules and regulations to
find out what is permitted. Even a good chimney can
function poorly if it is used incorrectly.
The cross-section of the chimney must be designed to fit the
fireplace. Use «2.0 Technical Data» to calculate the correct
chimney cross-section.
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fireplace and the hole in the chimney. See fig. 1 for
minimum dimensions.
Make sure that the flue pipe rises all the way up to the
chimney.
With a rear outlet, use a flue pipe bend with a sweep hatch
to allow sweeping.
Please note that it is extremely important for connections to
have a degree of flexibility. This is to prevent any movement
in the installation leading to the formation of cracks.
For recommended chimney draught, see «2.0 Technical
Data». For flue pipe dimension see "2.0 Technical Data".
NB: The chimney's diameter must be at least just as big
as the flue pipe.
NB! The minimum recommended chimney length is 3.5 m
from the flue pipe insert. If the draught is too strong, a flue
pipe damper can be installed and used to reduce the draught.
18
Operation under different weather
conditions
The effect of the wind on the chimney may have a significant
impact on how the stove reacts under different gust loads. It
may be necessary to adjust the air supply to achieve good
combustion.
4.5 Fitting a flue pipe with a top outlet
The product is supplied from the factory with the smoke outlet
fitted for the top outlet.
Fig. 19
1. Thread the flue pipe (A) through the top plate and place it
in the top smoke outlet.
2. Seal well with a gasket (B).