Fig. 24
D
C
2. Fasten the smoke outlet (A) to the rear outlet using the two
screws (C) from the inside of the burn chamber.
3. Fasten the cover (B) to the top outlet with the two screws
(D) from the inside of the burn chamber.
4. Reinstall the exhaust deflector.
5. Place the baffle.
Fig. 25
6. Place the gasket (B) on the edge of the flue pipe (A).
20
B
A
C
Fig. 26
D
7. Insert the flue pipe into the rear outlet.
NB: It is important for the joints/flue pipes to be sealed
completely. Air leaks may prevent them from operating
properly.
Product without convection plate
NB: If you will not use a convection plate, the product will have
different setup conditions (see fig. 1).