Periodical washing is also recommended so as to maintain the WTS that
supplies the humidifi er in good working condition. The water inside the
reverse osmosis system needs to be stirred periodically to avoid excessive
build-up of minerals on the membranes.
Important:
do not add disinfectants or anticorrosive compounds to the water, as
these are potential irritants;
the use of well water, industrial water or water from cooling circuits
and, in general, any potentially chemically or bacteriologically
contaminated water is prohibited.

3.1 Preparing to connect the power cables

C
1.
Unscrew the screw (A) and remove the cover (B);
2.
If the humidifi er is wall-mounted/installed on a horizontal support,
remove the corresponding metal knock-out using cutting nippers on
the bottom/rear panel (C);
3.
Fit the cable gland (D).

3.2 Electrical installation

Important:
before proceeding with the electrical connections, ensure that the unit
is disconnected from the mains power supply;
check that the unit's power supply voltage corresponds to the rated
data shown on the product label;
do not power on the unit if tilted or upside down: the transducers may
be damaged.
Connect the power cable to the terminal block through the cable gland.
Fig. 3.b
Note: to avoid unwanted interference, power cables should be kept
separate from probe signal cables.
The humiSonic electronic control board in fact comprises two boards,
a main board (1) installed horizontally, and an auxiliary card (2) installed
vertically.

3. ELECTRICAL CONNECTIONS

A
B
D
Fig. 3.a
L N
PE

2.6 Drain water

This is not toxic and can be drained into the sewerage system.
(Council Directive 91/271/EEC on Urban Waste Treatmen).
DRAIN WATER
Quick coupling
Typical temperature °C (°F)
J8
M9
M15
SOTTO/ BOTTOM
MAIN BOARD
C
N
M 15
Key:
A
board power supply input from transformer 24 V
B
transducer control;
C
valve power cables (L drain / R fi ll)
D
confi guration dipswitch
E
RESERVED
F
Power ON/OFF switch lights
G
TH humidity probe connection (IIC digital serial, part no.:
HYHU000000) built-in on part numbers UU**R*AS*1.
M14 remote ON/OFF (M14.1-M14.2)
M11 RS4845 serial (M11)
M15
front fan power
N
auxiliary card connection
AUXILIARY CARD
J8
tLan
Tx/Rx GND
J8
tLAN terminal connection (optional)
M9
tLAN AUX serial connector
M10
M10.1 - + proportional control signal/probe/humidistat
M10.2 - GND reference signal
M10.3 - +21 Vdc for power to active probes
M10.4 - Alarm relay - CO
M10.5 - Alarm relay - NO
J17
Reserved
Dipswitch confi guration: confi guration must be performed before
switching on the humidifi er (default position shown in Fig. 3.f ).
11
Direct version for room applic. +0300062IE - rel. 1.3 - 15.07.2019
OD 8 mm (0,32")
1-40 (33.8-104)
M10
J17
SCHEDA/BOARD
2
SCHEDA/BOARD
1
M11
M14
Fig. 3.c
A
B
G
G0
D
E
F
G
M 11
M 14
Fig. 3.d
M9
M10
J17
1
2
3
4
5
NO
COMMON
Fig. 3.e
ENG
Tab. 3.a