12.1 Ultrasonic humidifi er models for fan coils
and electrical specifi cations
The table below summarises the electrical data (power supply voltages)
of the various models, as well as their functional characteristics. Note
that some models can be powered at diff erent voltages, obviously with
diff erent current and humidity production values.
model
Humidity production
UU02RD%
UU02R1%
UU04RD%
UU04R1%
UU06RD%
6 (13.2)
UU06R1%
6 (13.2)
UU08RD%
8 (17.6)
UU08R1%
8 (17.6)
(1) tolerance allowed on rated mains voltage: -15%, +10%;
(2) tolerance on rated values: +5%, -10% (EN 60335-1);
(3) recommended values, referring to PVC or rubber cable in a closed conduit, 10 m
(32.8 ft) long; compliance with standards in force is always required;
(4)
max instant rated atomised water production: average atomized water production may
depend on external factors, such as: room temperature, water quality, atomised
water production distribution system
Important:
to avoid interference, keep power cables separate
from probe cables.
12.2 Technical specifi cations
Model
Flow-rate kg/h (lbs/h)
No. of transducers
Rated power (W) (2)
Application
Feedwater pressure bar (psi)
Feedwater temperature °C (°F)
Ingress protection
Electronic controller
Auxiliary voltage / frequency (V/ Hz)
Maximum auxiliary power (VA)
Probe inputs (general features)
Power supply to active probes (general features)
Alarm relay output (general features)
Remote enabling signal input (general features)
Serial communication
Environmental conditions
Ambient operating temperature °C (°F)
Ambient operating humidity (% rH)
12.3 Fuse table
Humidifi er P/N 48 Vdc power supply fuse
(1 fuse type 10.3 x 38)
UU02RD%
4 A
UU02R1%
4 A
UU04RD%
6 A
UU04R1%
6 A
UU06RD%
10 A
UU06R1%
10 A
UU08RD%
12 A
UU08R1%
12 A
12. GENERAL FEATURES AND MODELS
(2,4)
kg/h (lbs/h)
Power
(2)
2 (4.4)
180
2 (4.4)
180
4 (8.8)
330
4 (8.8)
330
480
480
690
690
Power supply fuse
(2 fuses type 5 x 20)
2.5 A
2.5 A
2.5 A
3.15 A
2.5 A
5 A
3.15 A
6.3 A
Power supply
(W)
Voltage
(1)
(V – type)
230
110
230
110
230
110
230
110
UU02R*
UU04R*
2 (4.4)
4 (8.8)
4
180
330
Can be selected for these signals: 0 to 10 Vdc, 2 to 10 Vdc, 0 to 20 mA, 4 to 20 mA
Input impedance: 20 kΩ with signals: 0 to 10 Vdc, 2 to 20 Vdc
100 Ω with signals: 0 to 20 mA, 4 to 20 mA
Voltage-free contact. Max resistance 100 Ω; max 5 Vdc open, 7 mA closed
RS485 (Carel/Modbus protocols) 1/8 unit load (96 kΩ)
250 Vac transformer fuse (1
fuse type 6.3 x 32 T)
3.15 A
3.15 A
3.15 A
3.15 A
3.15 A
3.15 A
3.15 A
3.15 A
Tab. 12.c
31
Direct version for room applic. +0300062IE - rel. 1.3 - 15.07.2019
Current draw
(2)
(A)
Cable
0,8
1,65
1,5
3
2,1
4,4
3
6,3
UU06R*
6 (13.2)
8
12
480
room
1 ... 6 (14.5...87)
5 ... 40 (41...104)
IP20
24V/50 – 60 Hz
3
21 Vdc, max 150 mA
24 V (max 3 W)
1 to 40 (33.8 to 104)
10...80
ENG
(3)
(mm
2
- AWG)
0,823 - 18
Tab. 12.a
UU08R*
8 (17.6)
16
600