integer variables (Modbus®: REGISTERS)
CAREL
Modbus®
82
209
AE: Restart fan time in standby for integrated probe reading
87
214
Slave 1 fi rmware release
89
216
Slave 1 humidifi er status
92
219
Parameter d3, slave 1: Operating hour counter
93
220
Slave 2 fi rmware release
95
222
Slave 2 humidifi er status
98
225
Parameter d3, slave 2: Operating hour counter
99
226
Slave 3 fi rmware release
101
228
Slave 3 humidifi er status
104
231
Parameter d3, slave 3: Operating hour counter
105
232
Piezoelectric transducer operating hour counter
106
233
Parameter d6 Time remaining to end of piezoelectric transducer life
107
234
Parameter AF: Piezoelectric transducer working life
112
239
Parameter bH: Enable probe TH as humidity limit
113
240
Parameter SL: Humidity limit set point
114
241
Parameter bP: proportional band for control with probe TH or external probe
115
242
Parameter bL: limit proportional band
"D"
digital variables (Modbus®: COILS)
CAREL
Modbus®
Just started fl ag
2
1
3
2
Humidifi er ready to produce
Humidity set point reached
4
3
5
4
Green LED
6
5
Red LED
Yellow LED
7
6
8
7
Remote On/Off
9
8
Low level
10
9
High level
11
10
Aux level
12
11
Autotest completed
14
12
BMS serial in tLAN mode
15
14
TAM enabled
16
15
TAM reading
17
16
Terminal connected
18
17
Production in progress
19
18
Fill
20
19
Drain
21
20
Transducer 1
22
21
Transducer 2
23
22
Fan
24
23
Alarm relay
25
24
Auxiliary relay

8.2 Production control via network

To control production via a he connection, confi gure the humidifi er using
following parameters:
Digital 27, Digital 37 and Integer 60 (Modbus 188)
When the D37 is at 1, the humidifi er excludes the external command
signals (external regulator or probes) and uses the value of Integer 60
(modbus 188) as like comand signal. The humidity production can be
managed in two modes:
To manage the production level in percentual mode:
Set D 37 = 1;
Set parameter A0 = 1 (Carel 20, Modbus 148, Proportional Mode);
Set integer variable 60 Carel (188 Modbus) to the desired level
(0-1000 = 0-100.0%).
To manage the production with a humidity probe managed by the
master:
Set D 37 = 1;
Set parameter A0 = 2 (Carel 20, Modbus 148, Humidity probe Mode);
Set integer variable 60 Carel (188 Modbus) to the desired level
(0-1000 = 0-100.0 rH%);
Set integer variable 52 Carel (180 Modbus) to the desired humidity
setpoin.
"D"
R/W
CAREL
Modbus®
R
26
25
R
27
26
R
28
27
R
29
28
R
30
29
R
30
31
R
31
30
R
33
31
R
34
33
R
35
34
R
36
35
R
37
36
R
38
37
R
39
38
R
43
42
R
44
43
R
46
45
R
47
46
R
49
48
R
50
49
R
51
50
R
52
51
R
When the D37 is at 1, if the communication is lost for the seconds settled
by parameter C4, is generated the "Master Offl ine" alarm (see alarms
table) and the production stops.
Production is activated/deactivated via digital parameter D27 (see
parameter table).
If D27 = 1 the humidifi er is disabled and production stops
if D27 = 0 the humidifi er is enabled and production is activated.
D27 is independent from the state of D37.

8.3 Washing cycle activation via network

A washing cycle can be performed at any time by managing digital
variable 38.
Setting the variable to 1 will immediately activate a washing cycle, even
if the unit is in standby, and even if both automatic washing and washing
due to inactivity are disabled by their corresponding parameters.
The variable will keep the value 1 throughout the duration of the washing
cycle, and will automatically be reset at the end of the cycle.
23
digital variables (Modbus®: COILS)
Manual drain
Disable from serial
Reset hour counter
Reset alarms
Washing due to inactivity activated
Status of dipswitch 8: parallel/series modulation
Functional test performed
Unit of measure
Slave 1 online
Slave 2 online
Slave 3 online
Enable control from serial (write probe value)
Wash activation from serial
Skip Autotest or washing while in progress
Reset piezoelectric transducer hour counter
Backup unit ready for production
Production limiting in progress (limit probe function)
On/Off control from keypad for master/slave network
On/off control from master unit keypad
On/off control from slave unit 1 keypad
On/off control from slave unit 1 keypad
On/off control from slave unit 1 keypad
Direct version for room applic. +0300062IE - rel. 1.3 - 15.07.2019
ENG
R/W
R
R
R
R/W
R
R
R/W
R
R
R/W
R
R/W
R/W
R/W
R/W
R/W
R/W
Tab. 8.e
R/W
R/W
R/W
R/W
R/W
R
R
R
R/W
R
R
R
R/W
R/W
R/W
R
R
R/W
R/W
R/W
R/W
R/W
Tab. 8.b

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido